background image

About this document

1.1  Content and purpose

This manual is part of the product. The manual 
contains important instructions for safe operation. 
Therefore, the manual must be carefully read 
before using the product. This manual describes 
the mounting, commissioning, maintenance and 
disassembly of the battery-powered hold-open 
system G-Ubivis XEA.  The manual’s text section 
is supported by figures in the picture section. The 
picture numbers in the text can be found at the 
bottom left in the figures for the respective chapter. 
Not every chapter in the text section has an figure in 
the picture section. 

1.2  Target group

The hold-open system’s mounting, commissioning, 
maintenance and disassembly must only be carried 
out by qualified personnel that have been authorized 
by dormakaba. The acceptance inspection must only 
be carried out by qualified personnel certified for 
this by dormakaba. The operation of the hold-open 
system may be carried out by any person who is 
mentally and physically able of doing so. 

1.3  Other applicable documents: 

•  Operating instructions 
•  Drilling template 
•  Information sheet about the use of hold-open 

systems

•  Building inspectorate approval

1.4  Documents storage

This manual must be kept during the service life of the 
product and must be passed on with the product.

Contents

About this document 

2

2 Safety 

3

Product description 

4

4 Mounting 

7

Check hold-open system 

9

Completion of mounting 

9

7 Operating 

9

Maintenance and care 

9

Maintenance from dormakaba 

10

10  Disassembly, recycling and disposal 

10

2

G-Ubivis XEA

2020-11

WN 058974 45532

dormakaba Operating instructions

About this document

1.5  Symbols used

1.5.1  Hazard categories

WARNING

This signal word indicates a situation of 
potential risk, which could lead to death or 
serious injury if not averted.

CAUTION

This signal word indicates a situation of 
potential risk, which could lead to minor or 
slight injury if not averted.

ATTENTION

This signal word indicates a situation of 
potential risk, which could lead to damage 
to property or the environment if not 
averted.

1.5.2  More symbols

TIPS AND RECOMMENDATIONS

This symbol indicates useful information for 
efficient and trouble-free operation.

 1 

Displays the image number in the text

1

Image number

2.

1.

Step-by-step figures

1

2

Position numbers of parts

Mounting on the hinge side DIN-L

Mounting on the hinge side DIN-R

Mounting on the opposite side to the 
hinge DIN-L

Mounting on the opposite side to the 
hinge DIN-R

Pay attention to note in the text

Reference to another manual

Summary of Contents for G-Ubivis XEA

Page 1: ...Operating instructions G Ubivis XEA WN 058974 4553215291 2020 11 EN ...

Page 2: ...l 1 4 Documents storage This manual must be kept during the service life of the product and must be passed on with the product Contents 1 About this document 2 2 Safety 3 3 Product description 4 4 Mounting 7 5 Check hold open system 9 6 Completion of mounting 9 7 Operating 9 8 Maintenance and care 9 9 Maintenance from dormakaba 10 10 Disassembly recycling and disposal 10 2 G Ubivis XEA 2020 11 WN ...

Page 3: ...m may only be mounted and used if the underside of the ceiling on both sides of the door is less than 1 m above the lower edge of the lintel Fig 1 1 m Distance to ceiling For smoke permeable subsurface constructions measure the distance to the smoke impermeable ceiling The smoke chamber must be above the clear passage area of the door A separate verification of suitability is required for the resp...

Page 4: ...nleitu ng G U bivis XEA WN 0589 73 4553 2 2018 05 DE 6 7 9 10 11 8 2 3 4 5 1 Parts included Components 1 End caps 2 Beam with smoke detector and battery holder 3 Lever 4 Slide rail with door holding device 5 Mounting plate with control unit 6 Decorative panel 7 Battery pack item no 57650000 Please note date of manufacture on the battery pack The battery may only be installed within 12 months of th...

Page 5: ...ry 28 s TIPS AND RECOMMENDATIONS After changing switch B the battery must be disconnected and reconnected after 30 s to take over the set function 3 2 2 Reset button and control LEDs 3 2 2 1 Reset button The reset buttons are located on the top and bottom of the beam The reset buttons both have the same functions Arming with manual reset To arm the smoke detector after the alarm has been triggered...

Page 6: ... by dormakaba Service 4 x every 7 s Battery almost empty Have the battery replaced by dormakaba Service 5 x every 7 s Magnet system dropped Press the reset button If the door holder is not working call dormakaba Service 6 x every 7 s Door holder failed Press the reset button with the door closed LED flashes red 4 x every 28 s Battery voltage too high if the door holder is not working call the dorm...

Page 7: ...s made 5B TIPS AND RECOMMENDATIONS Mount the slide rail flush with the mounting plate 1 Mount the slide rail on the mounting plate according to DIN R mounting 2 Plug in plug A connection between the slide rail and the control unit is made 6A B 1 Determine the desired size of the door opening angle If the door opening angle is less than 105 then only partially break the perforated area Only break t...

Page 8: ...er fits behind the screws 3 Place the battery packs on the screws and push them in the direction of the board The LED lights up white for about 2 s 4 Fix the battery packs with the screws The hold open system is now in operation The operation indicator flashes green 1 x every 28 s 14 ATTENTION Risk of unit damage Setting a release force too high may result in damage to the door hinges and the fast...

Page 9: ... for hold open systems 6 Completion of mounting If further structural work is carried out protect the smoke detector from dust 1 1 Stick the reset sticker next to the reset button on the bottom 2 Place the supplied dust cover on the smoke slots 3 Before the final commissioning remove the dust cover and carry out a further function test according to Section 5 1 7 Operating 7 1 Open and hold door 1 ...

Page 10: ...n systems which gives the building operators reliable security through the official seal of approval Because if not all door units have been properly tested the building operator may be liable for property damage and personal injury in the event of an accident Regardless of safety aspects regular maintenance also makes sense from an economic point of view Any damage or wear can thus be detected an...

Page 11: ... 11 160 75 428 150 81 58 43 16 11 142 160 8 75 142 428 160 8 16 11 43 81 58 150 75 428 160 43 16 11 43 81 71 150 75 428 150 43 81 71 43 16 11 160 75 max 16 max 16 max 26 max 26 10 10 10 10 min 860 min 860 min 860 107 107 11 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions 4 Mounting min 860 1B 1A 4 Mounting ...

Page 12: ...5 x 30 mm M5 x 20 mm 5 x 30 mm M5 x 20 mm A A B B 1 1 2 2 12 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions Maintenance from dormakaba 3B 3A 2A 2B 4A 4B ...

Page 13: ...M5 x 38 mm 2 0 2 5 Nm M5 x 38 mm 2 0 2 5 Nm M5 x 38 mm 2 0 2 5 Nm M5 x 38 mm 2 0 2 5 Nm 1 1 2 2 13 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions Maintenance from dormakaba 5B 5A ...

Page 14: ... 105 105 105 105 105 105 105 105 M5 x 10 mm 1 5 Nm M5 x 10 mm 1 5 Nm 1 4 4 3 14 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions Maintenance from dormakaba 6B 6A 7 ...

Page 15: ...2 5 5 2 5 8 10 Nm 2 5 3 Nm 140 8 0 1 1 1 3 3 3 2 2 2 4 15 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions Maintenance from dormakaba 9 10 11 8 ...

Page 16: ...1 1 3 3 2 2 4 4 approx 2 s 0 5 Nm 16 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions Maintenance from dormakaba 13 12 ...

Page 17: ...Nm Nm M4 x 10 mm 1 Nm M4 x 10 mm 1 Nm 1 1 1 3 2 2 2 17 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions Maintenance from dormakaba 14 15 16 M3 x 4 mm 1 Nm ...

Page 18: ...918 5 R e s e t 1 0 1 5 c m 1x 1 2 1 2 3 3 18 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions 5 Check hold open system 1 1 5 Check hold open system 6 Completion of mounting ...

Page 19: ...5 1 19 G Ubivis XEA 2020 11 WN 058974 45532 dormakaba Operating instructions 8 Maintenance and care 1 2 3 approx 2 s 0 5 Nm 1 1 1 3 3 3 2 2 2 2 4 8 Maintenance and care ...

Page 20: ...www dormakaba com dormakaba Deutschland GmbH DORMA Platz 1 58256 Ennepetal Germany T 49 2333 793 0 F 49 2333 793 4950 Translation of original manual subject to change without notice ...

Reviews: