3. Connect one output of the
Power Splitter
to the Doric
LED Driver
12 V input, the other to the
Power Extension Cable
.
4. Connect the
Power Extension Cable
to the
Fan Power Adapter 12 V
input.
5. Connect each channel of the LED driver to the input connectors of the
Fan Power Adapter
using M8 cables.
6. Connect
LEDFRJ
to the
Fan Power Adapter
using M8 cables.
7. Connect the 12 V power supply to the wall plug.
8. Ensure the power key and the interlock plug are properly set in place.
9. Apply current and voltage within the limits indicated in table
. On the
Combined LED
models, it is critical not to
block or insert objects into the grids as this could block airflow and reduce cooling efficiency.
10. When not in use, place plastic caps on the connectors for protection and cleanness.
2.2 FC Connector Installation
1. Clean the optical fiber connector before insertion. Use isopropanol and a lint-free wipe.
2. With an FC connector, the connector key must be oriented to enter within the receptacle slot to ensure proper
connection (Fig.
Figure 2.2:
FC connector, Fiber Installation
To reduce the risk of eye injury,
it is sound practice to NOT CONNECT/DISCONNECT OPTICAL
FIBERS when the light source is turned on
.
Chapter 2. Operations Guide