2. Insert cover plate, slide anti-rattle clip in position
(2" minimum from end), and attach end cap with two(2)
end cap screws.
End Cap
Bracket
End Cap Bracket Screws
C
Device must
be horizontally
leveled.
End
Cap
Screws
2" Minimum
Cover Plate
Anti-Rattle Clip
End Cap
J
1. Remove cover plate, insert end cap bracket into push bar
assembly against mechanism case. Level device, mark
and drill two(2) holes for Bracket Screws (see p.4). Fasten
end cap bracket screws to door.
Center case aligned
with mounting holes.
NOTE:
1. Install center case with both connectors
go through clearance between retractors
and center case.
2. Install support bracket on the top of
connector and retractor.
Support Bracket
After adjusting the rod lengths, Install connectors on both
concealed rods with rod screws.
Notch
of
Connector
of Device
L
C
L
Bottom
Rod
Top
Rod
Bottom Rod
Top Rod
Rod Screws
Connector
Trim
(Optional)
Center Case
Screws
E F
1 ³/
16
" Minimum clearance
(with end cap removed).
If device is too long for door,
see "CUT DEVICE"
on page 12.
1. DEVICE WITH TRIM - See "Trim Instructions".
2. EXIT ONLY - Mount center case to the door with four(4)
center case screws.
08. INSTALL TRIM (IF USING) AND SECURE DEVICE
CENTER CASE TO DOOR
07. INSTALL CONNECTORS
09. INSTALL MOUNTING BRACKET AND END CAP
08. INSTALL TRIM (IF USING) AND SECURE DEVICE
CENTER CASE TO DOOR. (CONTINUED)
7 / 12
Connectors for
1-3/4" door
thickness*
Refer to SCREW CHART on page 3
Door Stop
(On Frame)
Latch Release
Plunger Hole
(See p.6)
NOTE:
Position connector on top rod with its notch facing
towards top of door; repeat this step with connector at
bottom rod with its notch facing towards bottom of the door.
(*) Doors with cladding on the exit device side will require
spacers between the the rod and the connector.