10. CHECK TOP LATCH FOR HOLDBACK AND DEADLOCK.
38
2. Fully extended latchbolt should be in deadlock.
DEADLOCKED latchbolt cannot be pushed down into
the latch housing. If NO DEADLOCK, loosen strike screws
and adjust strike position.
Close
Open
1. Pushing on push bar will retract the latchbolt and open
the door. Latchbolt will stay retracted and device is in
HOLDBACK. If NO HOLDBACK adjust the screw in top
of retractor by screw driver.
Adjustment Screw
E
3. Apply third screw in hole of strike once
adjustment is complete.
3rd Strike Screw
3rd Strike Screw
E
Strike Screw
E
11. SECURE TWO(2) SIDE SCREWS
Apply second side screws through second holes in
connecting bar with second holes in retractor and tighten
two side screws.
Tighten Four(4)
Side Screws
Second
Side
Screws
Connecting Bar
L
DXAS106
DXAS215