50 Hz: G625 - G690 - G750XW/XF
OPERATION & MAINTENANCE MANUAL
55
60 Hz: G655 - G750 - G800 - G850XW/XF
CLEANING OF THE AIR FILTER ELEMENT
Clean the air filter element by using the most suitable
method for the work environment among the three
methods stated below.
1.
Use compressed air to clean the air filter element.
1) Use an air gun at a 90° angle from the inside of the
element.
2) Move air gun up and down the element to blow air
from inside to outside there is no more dust in the
element.
3) Do not use compressed air pressure exceeding 5
bars.
DANGER
Always wear protective goggles before starting work
in order to prevent injury from dust or foreign
substances in the element.
2.
Clean the element by washing it.
1) Before washing the element, clean the element by
using compressed air as described above.
2) Soak the element in the warm cleaning solvent for
10 minutes and then shake it back and forth for
approximately 5 minutes.
3) Rinse the element with clean water, drain the
water, and then dry it at room temperature. Fully dry
the element before reassembling.
CAUTION
Never use steam spray, gasoline, alkali or hot
cleansing solution to clean the element.
3.
In an emergency, temporarily clean the element by
using the following method.
1) Tap the end plate of the element to clean it
temporarily.
CAUTION
This method should only be used in an emergency
when cleaning of element is necessary and no
compressed air or cleansing solution is available.
Under no circumstances should the surface of the
element be hit or beaten with a hard object to shake
the dust off.
NOTE:
Before reassembling the element, make sure that
the filter paper is not wrinkled, the state of rubber
sealing is good, and tthe element is not deformed.
NOTE:
Do not reuse damaged elements under any
circumstances. When in doubt, replace the
element with a new one.
EDL022155A
EDL022156A
EDL022157A