MicroController Control System
Testing And Adjusting
Description of SAVE PARAM. Function
The SAVE PARAM. function allows the operator to transmit the Parameter values and Configuration data of
the chopper into the Console memory. It is possible to load 32 different programms.
The information saved in the Console memory can then be reloaded into another chopper using the
RESTORE function. The data that is available via the SAVE function is as follows:
- All Parameter Values (PARAMETER CHANGE).
- Options (SET OPTIONS).
- The Level of the Battery (ADJUST BATTERY).
Flow Chart showing how to use the SAVE function of the Digital Console.
1. Opening HEADING.
2. Press ENTER to go into the MAIN MENU.
3. The Display will show :
4. Press ROLL UP or ROLL DOWN button until
SAVE PARAM. appears on the display
5. The Display will show :
6. Press ENTER to go into the SAVE function.
7. If this facility has been used before, the type of chopper
data stored appears on the top Main with a 2 digit reference.
8. Keep pressing either ROLL UP or ROLL DOWN keys until
the second Main indicates a FREE storage facility.
9. Press ENTER to commence SAVE routine.
10. You can see the items that are being stored whilst
the SAVE routine is happening.
11. When finished, the Console shows :
12. Press OUT to return to the Opening HEADING.
KEYBOARD
MAIN MENU
PARAMETER CHANGE
MAIN MENU
SAVE PARAM.
SELECT : Mod.00
COMBISEM 3 DH
SELECT : Mod.01
FREE
READING...
ACCELER. DELAY (ETC.)
MAIN MENU
SAVE PARAM.
DISPLAY
H2 REG DHX.XX
48V 600A XXXXXX