38
OPERATING INSTRUCTIONS
12/154
J1939
SPN
J1939
FMI
CUMMINS
CODE
J1939 SPN DESCRIPTION
J1939 FMI DESCRIPTION
CUMMINS DESCRIPTION
3216
10
3725
Aftertreatment 1 Intake NOx
Abnormal Rate of Change
Aftertreatment 1 Intake NOx Sensor -
Abnormal rate of change
3216
13
3718
Aftertreatment 1 Intake NOx
Out of Calibration
Aftertreatment 1 Intake NOx - Out of
Calibration
3216
16
3726
Aftertreatment 1 Intake NOx
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Aftertreatment 1 Intake NOx - Data Valid But
Above Normal Operating Range - Moderately
Severe Level
3216
20
3748
Aftertreatment 1 Intake NOx
Data not Rational - Drifted
High
Aftertreatment 1 Intake NOx Sensor - Data not
Rational - Drifted High
3217
2
1861
Aftertreatment 1 Intake O2
Data Erratic, Intermittent or
Incorrect
Aftertreatment Intake Oxygen S ensor - Data
erratic, intermittent or incorrect
3218
2
3682
Aftertreatment 1 Intake Gas
Sensor Power Status
Data Erratic, Intermittent or
Incorrect
Aftertreatment 1 Intake NOx Sensor Power
Supply - Data erratic, intermittent or incorrect
3226
2
1694
Aftertreatment 1 Outlet NOx
Data Erratic, Intermittent or
Incorrect
Aftertreatment 1 Outlet NOx Sensor - Data
erratic, intermittent or incorrect
3226
4
1887
Aftertreatment 1 Outlet NOx
Voltage Below Normal or
Shorted to Low Source
Aftertreatment 1 Outlet NOx Sensor Circuit -
Voltage below normal, or shorted to low source
3226
9
2771
Aftertreatment 1 Outlet NOx
Abnormal Update Rate
Aftertreatment 1 Outlet NOx Sensor -
Abnormal update rate
3226
10
3545
Aftertreatment 1 Outlet NOx
Abnormal Rate of Change
Aftertreatment 1 Outlet NOx Sensor -
Abnormal rate of change
3226
13
3717
Aftertreatment 1 Outlet NOx
Out of Calibration
Aftertreatment 1 Outlet NOx Sensor - Out of
Calibration
3226
20
3749
Aftertreatment 1 Outlet NOx
Data not Rational - Drifted
High
Aftertreatment 1 Outlet NOx Sensor - Data not
Rational - Drifted High
3227
9
2683
Aftertreatment 1 Outlet O2
Abnormal Update Rate
Aftertreatment Outlet Oxygen Sensor Circuit -
Abnormal update rate
3228
2
3681
Aftertreatment 1 Outlet Gas
Sensor Power Status
Data Erratic, Intermittent or
Incorrect
Aftertreatment 1 Outlet NOx Sensor Power
Supply - Data erratic, intermittent or incorrect
3242
0
3311
Aftertreatment 1 Diesel
Particulate Filter Intake Gas
Temperature
Data Valid but Above Normal
Operational Range - Most
Severe Level
Aftertreatment 1 Diesel Particulate Filter Intake
Temperature - Data valid but above normal
operation
3242
2
3318
Aftertreatment 1 Diesel
Particulate Filter Intake Gas
Temperature
Data Erratic, Intermittent or
Incorrect
Aftertreatment 1 Diesel Particulate Filter Intake
Temperature - Data erratic, intermittent or
incorrect
3242
3
3317
Aftertreatment 1 Diesel
Particulate Filter Intake Gas
Temperature
Voltage Above Normal or
Shorted to High Source
Aftertreatment 1 Diesel Particulate Filter Intake
Temperature Sensor Circuit - Voltage above
normal, or shorted to high source
3242
4
3316
Aftertreatment 1 Diesel
Particulate Filter Intake Gas
Temperature
Voltage Below Normal or
Shorted to Low Source
Aftertreatment 1 Diesel Particulate Filter Intake
Temperature Sensor Circuit - Voltage below
normal, or shorted to low source
3242
15
3254
Aftertreatment 1 Diesel
Particulate Filter Intake Gas
Temperature
Data Valid but Above Normal
Operating Range - Least
Severe Level
Aftertreatment 1 Diesel Particulate Filter Intake
Temperature - Data Valid But Above Normal
Operating Range
3242
16
3253
Aftertreatment 1 Diesel
Particulate Filter Intake Gas
Temperature
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Aftertreatment 1 Diesel Particulate Filter Intake
Temperature - Data Valid But Above Normal
Operating Range
3246
0
3312
Aftertreatment 1 Diesel
Particulate Filter Outlet Gas
Temperature
Data Valid but Above Normal
Operational Range - Most
Severe Level
Aftertreatment 1 Diesel Particulate Filter Outlet
Temperature - Data valid but above normal
operation
3246
2
3322
Aftertreatment 1 Diesel
Particulate Filter Outlet Gas
Temperature
Data Erratic, Intermittent or
Incorrect
Aftertreatment 1 Diesel Particulate Filter Outlet
Temperature - Data erratic, intermittent or
incorrect
3246
3
3319
Aftertreatment 1 Diesel
Particulate Filter Outlet Gas
Temperature
Voltage Above Normal or
Shorted to High Source
Aftertreatment 1 Diesel Particulate Filter Outlet
Temperature Sensor Circuit - Voltage above
normal, or shorted to high source
3246
4
3321
Aftertreatment 1 Diesel
Particulate Filter Outlet Gas
Temperature
Voltage Below Normal or
Shorted to Low Source
Aftertreatment 1 Diesel Particulate Filter Outlet
Temperature Sensor Circuit - Voltage below
normal, or shorted to low source
Summary of Contents for 12/154
Page 2: ......
Page 4: ......
Page 84: ...80 MACHINE SYSTEMS 12 154 page ...
Page 86: ...82 MACHINE SYSTEMS 12 154 ...
Page 88: ...84 MACHINE SYSTEMS 12 154 ...
Page 90: ...86 MACHINE SYSTEMS 12 154 ...
Page 92: ...88 MACHINE SYSTEMS 12 154 ...
Page 94: ...90 MACHINE SYSTEMS 12 154 ...
Page 108: ......