OPERATING IN THE STANDBY MODE: (cont’)
tube and insert into the bottom end. Now, insert the feed tubes
back inside (reverse insertion positioning) the hopper to prevent
product from entering the freezing cylinder. The hole-side of the
feed tube should now be at the top.
When in the Standby Mode is it also advised to remove the valve
caps (typically the star shaped caps) from the dispensing aperture
of the valve body. You should also remove the drip tray and drip
tray cover. These parts should be sanitized upon removal and
dried for later use. The exterior of the machine, and specifically
the valve body, should also be cleaned and sanitized.
To exit Standby Mode and return to normal operation (Auto Mode),
press and hold the Wash button for five (5) seconds (machine will
beep 5 times), then release the Wash button. The machine will re-
turn to the Auto Mode when the Wash button is released and will
begin rotating the augers and cycling the refrigeration system so
that the product is frozen to the selected consistency.
When exiting the Standby Mode and returning to the Auto mode,
the feed tubes must be reversed from the Standby position with
the holes positioned on the top of the feed tube to the normal op-
erating position with the holes being nearer the bottom so that the
product mix can flow into the freezing cylinder. Failure return the
feed tubes to the Auto position may result in damage to the ma-
chine.