DONPER
USA
—USER MANUAL
36 — COPYRIGHT DONPER USA 2015
Mix is too soft.
1. Mix in the freezing cylinder is
too warm.
2. The mix is aged or over- agi-
tated.
3. Not enough space around
the machine or obstructions
around the machine that pre-
vent proper air flow for the re-
frigeration system to cool
properly.
4. Worn scraper blades.
1. Increase the firmness
level setting (higher num-
ber).
2. Replace old mix with
fresh product.
3. Space machines
properly to allow for ade-
quate air flow across the
condenser (8” in between
machines and 12” behind
each machine is optimal).
4. Check scraper blades
for signs of wear. Replace
if there is any damage or if
they are unevenly worn.
5. Clean the condenser to
allow better air flow.
Make
sure that the machine un-
plugged before removing
the back panel to clean
the condenser.
The mix in the hop-
per is too cold.
1. The temperature setting on
the thermostat needs adjust-
ment.
2. Faulty thermostat.
1. Adjust hopper thermo-
stat temperature.
2. Call the Donper USA
service line to have ther-
mostat inspected/
replaced.
The mix in the hop-
per is warm.
1. The temperature setting on
the thermostat needs adjust-
ment.
2. Faulty thermostat.
3. Dirty condenser.
1. Adjust hopper thermo-
stat temperature.
2. Call the Donper USA
service line to have ther-
mostat inspected and/or
replaced.
3. Clean the condenser.
Make sure that the ma-
chine is completely turned
OFF.