Installation, Operation and Maintenance Manual
Unimaster Dust Collectors – Series UMA 40-750
32
MAINTENANCE
6 Fit new filter bag assembly into supporting frame, feeding individual filter
bags between locating bars, and fold collar over peripheral sealing flange.
7 Prior to fitting wire mesh inserts, any material edgings that need replacing
should be fitted around the three edges of the insert that do not have the
insert frame joint. The inserts should then be fitted, edging first, into the filter
bags.
(Filter assembly replacement)
8 Slide filter assembly into the collector using the guides until the bottoms of
the filter bags make contact with the shaker bar.
9 Locate individual filter bags in shaker bar.
10 Slide filter assembly fully home and tighten securing wing nuts to form an
airtight seal. Check top frame is against sealing rubber (see fig. 17).
11 Replace access door and discharge cowl (or, if fitted, the absolute filter).
12 If in doubt regarding the safe disposal of the used filter bag assembly, consult
your local regulations.
Figure 13 Section through fan assembly (UMA 40MM)
Nut
Washer
Pulley
Screw
Spacer
End cap
Shaft
Roller bearing
Housing
Bearing locator
Spacer
Bearing locator
Ball bearing
End cap
Spacer
Screw
Impeller
Washer
Nut
Pack with
grease