![Donaldson Torit UMA 100H Installation, Operation And Maintenance Manual Download Page 14](http://html1.mh-extra.com/html/donaldson-torit/uma-100h/uma-100h_installation-operation-and-maintenance-manual_2520677014.webp)
Installation, Operation and Maintenance Manual
Unimaster Dust Collectors – Series UMA 40-750
14
Unimaster standard dust collectors
with dust container
UMA 40, UMA 40MM and UMA 72
These collectors are supplied fully assembled.
For UMA 40 and 40MM collectors, lift into position using the fork lifting method.
For UMA 72 collectors, lift into position using either the four-point lifting method
or the fork lifting method.
If the contaminated air inlet requires repositioning, make sure sealant
is used when repositioning the inlet blanking plate, in order to ensure
an effective seal.
UMA 103, UMA 153, UMA 253 and UMA 456
These collectors are supplied in two sections.
1 Using the four-point lifting method, lift the bottom assembly into position
using the lifting brackets provided.
2 Using spirit levels, line up the bottom assembly both horizontally and vertically,
using shims under legs where required.
3 Remove lifting brackets from the joint flange.
INSTALLATION
Figure 7 Applying sealant to bottom assembly
Upper section
Apply sealant to
joint flange
Bottom assembly