INSTALLATION
UMA 70V, UMA 100V, UMA 150V, UMA 250V, UMA 450V and UMA 750V
These collectors are supplied fully assembled.
When the collector is fitted with an explosion relief assembly, the
explosion relief area is suitable for the collector volume only. Additional
protection may be required when mounting onto other vessels.
1 Using the sealant provided, apply two beads of sealant to the site seating
flange, one each side of the fixing holes, as shown in figure 11 (if
required, details of mounting flange fixing positions are provided in
dat
a
sheet of UMA 40,UMA 70-250,UMA450 and UMA 750).
2 Lift the collector using either the four-point lifting method or the fork lifting
method, onto the site seating flange.
3 Secure the joint with fixings to suit the application and remove excess
sealant.
Unimaster venting type
dust collectors
Figure 11 Applying sealant to site sealing flange
UMA hopper type or
venting type collector
Site seating flange
Apply sealant to
joint flange