Dryflo, MMA and MMB
16
Machine Installation
1. Apply a generous amount of sealant when installing attachments.
2. Position the collector above the mist-capture zone. See Collector Positioning.
3.
Do not allow a P-Trap to form when using flexible duct. See Flex-Duct Positioning.
4.
On enclosed machine installations, mount the collector as far from the chip conveyor opening as possible. Installing too
close allows the negative pressure created by the collector to draw clean shop air, not mist, into the collector. See Enclosed-
Machine Installation.
5.
On open machine installations, position the collector’s pick-up hood a minimum of 12-inches from the mist source. Avoid
mounting the pick-up hood too close to the mist source of an open machine such as a wet surface grinder. Installing too close
can shorten filter life as the collector will collect large droplets and particulate instead of mist. See Open Machine Installation.