INSTALLATION INSTRUCTIONS
2-44
L025317 Issue 5 July 2014
AIR FLOW SETTINGS
The air flow through the laser head and thereby the consumption of
compressed air is controlled by an internal switch valve.
In order to reach the specified cooling capacity the line pressure before the
laser head must be set to approximately 3.5 bar. This results in an air flow of
400 litres per minute if the switch valve is open.
In order to prevent the laser from damage the switch valve opens for 60
seconds each time the marking system is set to its “Ready” state. After this
sequence the switch valve opens every 10 seconds. Check and re-adjust
the line pressure during the first off cycles after the initial 60 seconds
cooling period. The flow control mechanism monitors the temperature of
the laser source and adjusts the length of the periods where the switch
valve is open. If the laser is running cold, the air flow is engaged for 1
second. Once the laser heats up this period gets longer until the open state
would last for more than 9 seconds. At this point the valve will stop
switching and remains open.
Air Flow without Air Chiller
D120i
These are examples of typical air flows for the D120i.
D120i Ambient temperature (in
°
C) vs. maximum mark duty cycle (in %)
depending on airflow (in LPM)
Without air chiller
Summary of Contents for D120i Blue IP
Page 1: ...Domino D Series Product Manual ...
Page 3: ...L025317 Issue 5 July 2014 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 6: ... 6 L025317 Issue 5 July 2014 ...
Page 8: ... 8 L025317 Issue 5 July 2014 ...
Page 9: ...L025317 Issue 5 July 2014 9 ...
Page 20: ... 20 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 22: ...HEALTH SAFETY 1 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 42: ...HEALTH SAFETY 1 22 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 58: ...INSTALLATION INSTRUCTIONS 2 16 L025317 Issue 5 July 2014 X2 Connector Schematic Beacons ...
Page 70: ...INSTALLATION INSTRUCTIONS 2 28 L025317 Issue 5 July 2014 X23 Connector Schematic RS232 COM1 ...
Page 104: ...INSTALLATION INSTRUCTIONS 2 62 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 109: ...OPERATION L025317 Issue 5 July 2014 3 5 ...
Page 110: ...OPERATION 3 6 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 164: ...OPERATION 3 60 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 166: ...TECHNICAL REFERENCE 4 2 L025317 Issue 5July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 188: ...TECHNICAL REFERENCE 4 24 L025317 Issue 5July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 218: ...APPENDIX FONTS A 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 220: ...APPENDIX BARCODES B 2 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 224: ...APPENDIX BARCODES B 6 L025317 Issue 5 July 2014 THIS PAGE INTENTIONALLY LEFT BLANK ...