15
Cable cross sections and cable lengths for caravan/motorhome:
1.10 Electrical installation
The electrical installation must be in
accordance with the national regulations
of the respective countries.
The connection cables must be routed in a
way to prevent contact with hot compo-
nents of the unit/burner or with sharp
edges.
Changes to the internal electrical installa-
tion or the connection of other electrical
components (e.g. external fan) to the
internal wiring of the appliance will render
any claims from warranty and product lia-
bility void!
The electrical installation shall be carried
out by qualified personnel only.
WARNING
The power should be supplied by a pro-
perly grounded socket outlet or a groun-
ded non-detachable connection. Where a
socket outlet with mains supply is used,
the outlet must be freely accessible.
Should the connection cable be damaged,
have it replaced by Dometic Customer
Services or by qualified personnel to
avoid hazards.
We recommend leading the power supply via a
board-side fuse protection.
1.10.1 Mains connection
1.10.2 Battery connection
The machine's 12V connection cable is connec-
ted (observing correct polarity) to a terminal
strip. The wiring for the heating element (refer to
A, B wiring diagram connections; connection
cable white/red) must be direct and by the shor-
test possible route to the battery or electric
generator.
AWG 11
< 20 ft
AWG 9
> 20 ft
min. AWG 13
Cross section
Length
Motorcaravan &
Caravan (
inside
)
Caravan (
outside
)
2,5mm²
Fig. E30
THE SIGN OF COMFORT
Summary of Contents for RML 8551
Page 18: ...18 Fig E35 2 0 Tables and wiring diagrams 2 1 Wiring diagrams 2 1 1 Wiring diagram RM 8xx0...
Page 19: ...19 Fig E36 2 1 2 Wiring diagram RM 8xx1 THE SIGN OF COMFORT...
Page 20: ...20 Fig E37 2 1 3 Wiring diagram RM 8xx5...
Page 21: ...21 Fig E38 2 1 4 Wiring diagram RM 8xx5 with electrical doorlock optional THE SIGN OF COMFORT...
Page 23: ...23 THE SIGN OF COMFORT...
Page 24: ......
Page 47: ...23 THE SIGN OF COMFORT...
Page 48: ......