Smart Touch Cabin Control Specifications
No . Button
Description
y
Temperature
Indicator
Displays the temperature based on the
sensor indicator.
u
Status
Shows if a fault has occurred
i
Schedule
Shows a schedule program is active and
the specific times and days
o
Up
Increases the set point one degree with a
press and release
a
Down
Decreases the set point one degree with
a press and release
s
Power
Toggles between On and Off mode
4 Specifications
This section describes the display, sensor, cabling,
environmental, and electrical specifications for the unit.
Installation Specifications
Display Dimensions
Display Panel
4.3 x 2.9 in. (110 x 73 mm)
Panel Cut Out
2.9 x 2.2 in. (74 x 55 mm)
Cable Lengths
Display Cable Self Contained
15 ft (4.6 m) Standard
Display Cable Central System
30 ft (9.1 m) Standard
Alternate Air Sensor (optional)
7 ft (2.1 m) Standard
Alternate Air Sensor Central
System (optional)
30 ft (9.1 m) Standard
Outside Air Sensor (optional)
15 ft (4.6 m) Standard
All custom cable lengths
supplied in standard 5.0 ft
(1.5 m) increments
75 ft (22.9 m) Maximum
Sensor Inputs
Ambient or Inside Air Temp
1
High Refrigerant Pressure
1
Low Refrigerant Pressure
(optional)
1
Alternate Inside Air Temperature
Sensor (optional)
1
Outside Air Temperature Sensor
(optional)
1
Pump Sentry Condenser Coil
Sensor (optional)
1
Humidity Sensor (optional)
1
Operational Specifications
Environmental
Set Point Operating Range
65–85 °F
(18–29 °C)
Ambient Temperature
Operating Range Displayed
5–150 °F
(-15–66 °C)
Sensor Accuracy
±2 °F @ 77 °F
(±1 °C @ 25 °C)
Minimum Operating
Temperature
0 °F (-18 °C)
Maximum Ambient Operating
Temperature
180 °F (82 °C)
Electrical
Low Voltage Limit 110–120 Volt
Units
95 VAC
Low Voltage Limit 208–240
Volt Units
195 VAC
Low Voltage Processor Reset
50 VAC
Line Voltage
100 through 240 VAC
Frequency
50 or 60 Hz
Fan Output
6 A @ 115 VAC
6 A @ 230 VAC
Valve Output
1/4 A @ 115/230 VAC
Heater Output
(using valve relay)
15 A @ 115 VAC
10 A @ 230 VAC
Aux Heater Output
(using off-board relay)
30 A @ 115 VAC /
230 VAC
Pump Output
1/4 HP @ 115 VAC
1/2 HP @ 230 VAC
Compressor Output
1 HP @ 115 VAC
2 HP @ 230 VAC
Maximum Rh Conditions
99% Non Condensing
Power Consumption
< 5 W