8
EN
Wiring Diagrams
5 Wiring Diagrams
The following diagrams show the component
connections for the direct expansion (DX) and chilled
water (CW) systems.
5 .1 Understanding the DX Wiring
Diagram
WARNING: ELECTRICAL SHOCK .
Turn the power off before opening the electrical
box. Failure to do so could result in death or serious
injury.
Run Capacitor
Low-Pressure
Switch
High-Pressure
Switch
Optional
DC Blower
Comp L1
Pump L1
Pump L2
0-10 VDC
GND
Fan L1
Comp L2
Compressor
Inside Temperature Sensor Jack
Not Active
Optional Water-Out Temperature Sensor
Ground
Start
Capacitor
Start Relay
1
6
4
5
2
L2
AC
Fan
Fan Run
Capacitor
L1
L1
L2
Pump or
Pump Relay Panel
Temperature Sensor Selection Jumper
Low-Pressure Switch Jumper
Reversing Valve or
Electric Heat
Gate Terminals to Aux Heat Relay
Display Jacks (for 8- or 6-pin Display and Cables)
Optional Outside Air Temperature Sensor
5
Wiring Diagram - DX
Summary of Contents for MCS-CTRL
Page 42: ...42 EN Smart Touch Cabin Control...