![Dometic MCS-CTRL Installation And Operation Manual Download Page 33](http://html1.mh-extra.com/html/dometic/mcs-ctrl/mcs-ctrl_installation-and-operation-manual_2518494033.webp)
33
EN
Control Parameters
9 .10 .2 Control Parameters Navigation
CW Operational Settings
Water Valve Force
Open
Off [On/Off]
Water Temp Differential
15 °F/8 °C [5–25] °F
or [3–14] °C
General Settings
High Fan Speed
95 [35–95]
Medium Fan Speed
61 [32–85]
Low Fan Speed
50 [30–75]
Inside Temp Calibration
±50 °F or ±25 °C
Temperature Units
Auto [Auto/°F/°C]
Reversed Fan SPD in Heat
On [On/Off]
Aux Heat Option
Off [Off/On]
Fan Motor Type
SP [Split Capacitor/Shaded Pole]
Filter Hours Setting
Off [100–2,500]
Filter Hours Reset
Clear
CAN Bus Unit ID*
1 [1–255]
CAN Bus Group ID*
1 [1–255]
Voltmeter Calibration
[70–140 VAC] or [170–260 VAC]
Set Point Temp Differential
2 °F (1 °C ) [1–2] °F or [0.5–1.0] °C
Humidity Mode Min Temp
50 °F (10 °C) [40–75] °F or [5–25] °C
Auto Fan Speed Temp Diff
2 °F (1 °C) [1–3] °F or [0.5–1.5] °C
Supply Air Temp Limit*
Off [Off/[95–140] °F or Off/[35–60] °C]
DX/CW Mode
Set by jumper/DX Override/CW Override
Inside Temp Sensor
Auto [Auto/Display/Alt. Air]
Fan Operational Mode
Continuous [Continuous/Cycled]
Dual Temp Set Points
Off [On/Off]
Humidity Sensor Limit
60% [50%–80%]
DX Operational Settings
Compressor Start Delay
15 sec [5-135] sec
Failsafe Level
Fails Not Detected/
Fails detected and displayed with Lockouts
Low Voltage Monitor
Off/95–120 VAC or Off/195–240 VAC
De-Ice Cycle
Enabled
[Disabled/
Enabled with 5 °F (3 °C )Sensor Differential/
Enabled with 7°F (4°C) Sensor Differential]
Pump Sentry
Off [Off/100–150 °F or Off/40–65 °C]
Pump Operational Mode
Continuous or Cycled
Low-pressure Detection
Set by Jumper/Disabled
Seawater Low Limit Adj.
40 °F [35–50] °F
Heat Pump/Cool Only
Heat Pump [Heat Pump/Cool Only]
Control Parameters
General Settings
DX Operating Settings*
CW Operating Settings*
Memorize Settings
Recall Memorized
Recall Defaults
*
To activate this feature, a
dditional hardware or software is required
and must be enabled in the parameters
.
Summary of Contents for MCS-CTRL