background image

 

REMOTE CONTROL         
GP-ICR-50

User Manual

GP-ICR-50

SHORE POWER
UNIT READINGS

INVERTER

ON/OFF

CHARGER

ON/OFF

ENTER / SET

BACK

UNIT SETUP
REMOTE SETTINGS

®

© 2021 Go Power!

Worldwide Technical Support and Product Information 

gpelectric.com

Go Power! | Dometic

201-710 Redbrick Street Victoria, BC, V8T 5J3

Tel: 1.866.247.6527

79498_MAN_GP_ICR_50_Rev_C

Summary of Contents for Go Power! C Series

Page 1: ...EADINGS INVERTER ON OFF CHARGER ON OFF ENTER SET BACK UNIT SETUP REMOTE SETTINGS 2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power Dometic 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 79498_MAN_GP_ICR_50_Rev_C ...

Page 2: ...the Go Power Remote Control Please retain this manual for future reference Product Packaging Please safely store the packing the GP ICR 50 was delivered in or please recycle the packaging components as outlined below Corrugated fiberboard main box internal sleeve Plastic screen protection film screw plastic bag LDPE Low Density Polyetheylene CFB 3 4 7 CFB 3 4 7 CFB 3 4 7 Corrugated Recycles www co...

Page 3: ...TEM OVERVIEW 10 3 2 UNIT DIMENSIONS 14 3 3 MOUNTING REQUIREMENTS 14 3 4 INSTALLATION TOOLS 14 3 5 MOUNTING PROCEDURE 15 4 OPERATION 16 4 1 REMOTE NAVIGATION 16 4 2 SUB MENU ITEMS OPTIONS 18 4 3 SHORE POWER MAX MENU 19 4 4 UNIT READINGS MENU 20 4 5 UNIT SETUP MENU 21 4 6 REMOTE SETTINGS MENU 26 5 WARRANTY RETURN PROCEDURE 28 6 END OF LIFE RECYCLING INFORMATION 29 APPENDIX 30 CONTENTS ...

Page 4: ...mproper operation may have a risk of electric shock or damage to equipment and property GENERAL SAFETY WARNING Limitations on Use CAUTION Equipment Damage This equipment is NOT intended for use with life support equipment or other medical equipment or devices This product is designed for indoor compartment installation It must not be exposed to any liquids moisture of any type Only use components ...

Page 5: ...y be impaired EQUIPMENT SAFETY WARNING Lethal Voltage Review the system configuration to identify all possible sources of energy Ensure ALL sources of power are disconnected before performing any installation or maintenance on this equipment Confirm that the terminals are de energized using a validated voltmeter rated for a minimum 1000 VAC and 1000 VDC to verify the de energized condition Do not ...

Page 6: ...other electrical parts Never charge a frozen battery Never use old or untested batteries Check each battery s label for age type and date code to ensure all batteries are identical If a battery must be removed always remove the grounded terminal from the battery first Make sure all devices are de energized or disconnected to avoid causing a spark IMPORTANT Use the battery types recommended by Go P...

Page 7: ...hat the information is accurate correct reliable or current The specifications in this manual are for reference purposes only and are subject to change without notice For additional information please see www gpelectric com DISCLAIMER Go Power disclaims liability for any direct indirect or incidental damages caused by or in case of installation not performed following the instructions and cautions...

Page 8: ...he remote control like brightness power save mode Unit Setup Menu When the icon is pointing to unit readings you are in the unit settings menu These are the Inverter Charger main settings like search watts battery types etc Unit Readings Menu When the icon is pointing to unit readings you are in the unit readings menu These are for display only and no settings can be changed in this menu Shore Pow...

Page 9: ...g function of the Inverter Charger Green Inverting No colour Not Inverting RJ 45 Cable Entry Point Remote control cable entry point Mounting Holes These 4 holes are used to attach the GP ICR 50 to a suitable wall using the 4 x Phillips screws included 15 RJ 45 Cable Entry Point WARNING Turning the unit OFF does not dis connect the batteries or AC Power Source Therefore the AC output load is still ...

Page 10: ... diagrams on pages 12 15 show how the GP ICR 50 and Inverter Charger typically installed in a mobile RV application The diagrams show where the remote and Inverter Charger are installed and how the mobile power system can be integrated with a Go Power RV Solar Kit sold separately by Go Power please contact us direct 3 INSTALLATION ...

Page 11: ...able to Battery Bank Battery Bank Cables From Solar Charge Controller GP IC Remote AC Power OUTPUT to RV appliances IC Series Inverter Charger IC Series Inverter Charger Cables to from Battery Bank AC Power INPUT from Shore Power Generator Fuses Breakers not shown INSTALLATION ...

Page 12: ...Transfer Switch Solar Panel Solar Panel Solar Charge Controller Refrigerator Vent Cover or Cable Entry Plate Fuse Battery Temperature Sensor Typical RV Solar Kit sold separately by Go Power To Battery Bank To Battery Bank Earth Ground RV Boat Ground INSTALLATION ...

Page 13: ...ower 120 240 VAC el Sub Panel 120 VAC 240 VAC cabin install Remote Control Optional Battery Disconnect Switch not required if circuit breaker is used Battery Bank Fuse or Circuit Breaker IC Series Inverter Charger DC Panel 120 VAC INSTALLATION ...

Page 14: ...an dry and protected Make sure the LCD screen is visible and access to the menu navigation buttons is clear and un obstructed Always check for hidden electrical wires pipes and cables before drilling cutting or screwing into walls cabinets 3 4 INSTALLATION TOOLS SHORE POWER UNIT READINGS INVERTER ON OFF CHARGER ON OFF ENTER SET BACK UNIT SETUP REMOTE SETTINGS 2 7 69mm 1 22 31mm 3 9 98mm 3 3 83mm 5...

Page 15: ... 8 x 3 4 screws 4 Route one end of the remote control cable through the wall opening to the Inverter Charger plug this end into the REMOTE port 5 Take the other end of the remote cable and plug it into the rear of the GP ICR 50 The remote should power up if the Inverter Charger is connected to the battery bank All power to operate the GP ICR 50 is provided by the Inverter Charger through the remot...

Page 16: ... UNIT SETUP REMOTE SETTINGS Go Power Initializing DC Status 11 68 V 0 0 A DC Status 11 68 V 0 0 A DC Status 11 68 V 0 0 A DC Status 11 68 V 0 0 A DC Status 11 68 V 0 0 A 1 Press the Inverter ON OFF button to turn the Inverter on which then automatically powers the remote up The remote will take up to 10 seconds to go to the default home screen which is DC Status in the unit readings sub menu As sh...

Page 17: ...GS 4 To navigate through the sub menu options first enter the menu using the ENTER SET button 5 Then press the down menu select button to move to the next sub menu option notice the menu arrow does not move and again to move to the next sub menu option you will cycle back to the start when you have scrolled through all available options in that sub menu The unit readings menu options tree is shown...

Page 18: ...03 VAC Dropout 80 100V 85V 04 Max Cha Time 0 0 25 5 HR 12 0 HR 05 Battery Type Gel Flooded AGM 1 AGM 2 Custom AGM 1 06 Charge Rate 50 IC 2000 40 IC 3000 80 07 Final Charge Multi Stage Float Silent Multi Stage 08 ABS Chg Time 0 5 24 0 HR 2 0 HR 09 Equalization Active Inactive Inactive 10 Rebulk Volt 12 0 16 0 VDC 12 1 VDC Remote Settings Model Revisions Remote 1544 1 Inverter 1537 1 Read Only Load ...

Page 19: ... size of the two AC power sources The IC Series has 2 inputs AC HOT 1 and AC HOT 2 but the current is only monitored on AC HOT 1 If you wire the Inverter Charger in Single In Single Out 50A configurations see the IC Series user manual the shore power max setting should be set to 1 2 the input breaker size which will be 25A 50A 2 25A This is because half the current will pass through AC HOT 1 and t...

Page 20: ...charged charging mode from into the battery bank A negative value e g 35 0A shows that the batteries are dis charging and the Inverter Charger is inverting A positive value e g 40 0A shows that the batteries are charging and the Inverter Charger is in charging mode State indicator PT Pass Through PS Powershare CHG Charging INV Inverting 2 AC INPUT The first value is showing the total AC Amps being...

Page 21: ...h should be connected to the battery bank Trans Displays the temperature of the main power transformer inside the Inverter Charger Fets Displays the temperature of the field effect transistors FETs inside the Inverter Charger 5 FAULT CODE Menu Heading Selections Adjustments Range Default Setting Unit Setup 01 Search Watts OFF 5 50W 5W 02 LowBatCutOut 9 0 12 2 VDC 10 5 VDC 03 VAC Dropout 80 100V 85...

Page 22: ...ange is 9 00 to 12 2 VDC increments by 0 01 VDC If you want to cycle the batteries slightly but don t want to discharge them more than 20 then set the LBCO from 11 5 12 2 VDC In some applications such as those installed in an off grid home or when doing a lot of boon docking dry camping in your RV you may want to cycle down to 50 by setting the LBCO from 10 0 to 11 4 VDC Higher discharge rates wil...

Page 23: ...Sets the level at which the charging voltage is held constant during an absorption cycle The default value is 14 0V and the range is 12 0 to 16 0V increments by 0 1 VDC Float Sets the level at which the charging voltage is held constant during a float cycle The default value is 14 0V and the range is 12 0 to 16 0 VDC increments by 0 1 VDC Equalize Sets the level at which the charging voltage is he...

Page 24: ...5 80 which means setting the charge rate to 80 For slow charge rates a simple guideline is C 20 so a slow charge rate for the 400 Amp hour capacity battery bank will have a slow charge rate of 20 Amps hour 400 20 20 which means setting the charge rate to 20 The default setting is 80 and the range is from 0 100 in 10 increments 7 FINAL CHARGE The final charge setting is used to adjust what charging...

Page 25: ...en and oxygen gas Ensure the battery compartment has adequate ventilation to dissipate this gas to avoid explosions Ensure your batteries can be equalized only equalize batteries that can be equalized Consult your battery manufacturer for further information Equalizing batteries not designed for equalizing can permanently damage them Gel and AGM2 battery types are not permitted for equalizing Whil...

Page 26: ...elp the customer service personnel help you 2 LOAD DEFAULTS This setting restores all factory default values for both the remote control and the Inverter Charger To restore factory defaults select the menu then set to YES and confirm 3 SET PIN This setting can be used to set a pin number to lock the customizable setting menu options on the Inverter Charger and remote control This feature is useful...

Page 27: ...gle The default setting is 80 and the range is 0 100 10 increments 4 7 FUNCTION INDICATION The function indication displays which mode the Inverter Charger is presently in which is displayed in the lower left section of the screen The three functions are invertering INV charging CHG power sharing PS and pass through PT 4 8 ERROR STATES Error Code Description 0 Overload Protection Failure 1 Power O...

Page 28: ... Beeping Counts for Error Modes Beep Counts Description 1 UTP Under Temp Protection 2 OTP Over Temp Protection 3 OVP Over Voltage Protection 4 UVP Under Voltage Proection 5 Short circuit or OLP Over Load Protection OPERATION ...

Page 29: ...ction of our website to troubleshoot the problem If trouble persists 1 Call your Go Power Technical Support team 1 866 247 6527 or 2 Return defective product to place of purchase Unless approved by Go Power Management all product shipped collect to Go Power will be refused Test items or items that are not under warranty or units that are not defective will be charged a minimum bench charge of 50 0...

Page 30: ... being recycled properly is tricky If your in doubt just ask Recyclers that are certified should gladly show you their certification If the re cycler is certified chances are very high that they are recycling responsibly To find your local e waste centre please contact your local municipality The following website also has information on local recycling centres www earth911 com recycling center se...

Page 31: ......

Page 32: ...NIT SETUP 02 LowBatCutOut UNIT SETUP 03 VAC Dropout UNIT SETUP 04 Max Cha Time 01 SEARCH WATTS OFF 50W OFF 02 LowBatCutOut 9 00V 10 5V 10 5V 03 VAC Dropout 80V 85V 85V 04 Max Cha Time 0 0HR 25 5HR 12 0HR Model Revisions Remote 1544 1 Inverter 1537 1 Load Defaults Edit No Set PIN Input Old PIN 0000 Input New PIN 0000 Input New PIN Unlock SETUP Temperature Batt 20 0 Trans 30 5 Fets 30 6 APPENDIX ...

Page 33: ...AGM1 AGM2 Custom AGM1 06 Charge Rate 0 100 80 07 Final Charge MUTI STAGE FLOAT STAGE SILENT STAGE MUTI STAGE 08 ABS Cha Time 0 5Hr 24 0Hr 2 0Hr Power Save OFF 60MIN OFF Screen Setup Contrast 00 100 80 Pwr Up Always YES NO YES UNIT SETUP 09 Equalization 09 Equalization ACTIVE INACTIVE INACTIVE UNIT SETUP 10 Rebulk Volt 10 Rebulk Volt 12 0 16 0V 12 1V APPENDIX ...

Page 34: ... 2021 Go Power Worldwide Technical Support and Product Information gpelectric com Go Power 201 710 Redbrick Street Victoria BC V8T 5J3 Tel 1 866 247 6527 79498_MAN_GP_ICR_50_Rev_C ...

Reviews: