EN
FreshJet
Installation
11
Note on electrical system
•
Only a qualified electrician should connect the roof air conditioner to the
electrical power.
•
Check that the voltage specification on the type plate is the same as that of the
power supply.
•
If the lighting should also be switched on without a 230 V voltage supply, make
sure that there is a 12 V
g
power supply line from the battery to the roof air
conditioner.
•
Do not lay the 230 V mains cable and the 12/24 V
g
cable together in the same
cable duct.
•
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
•
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
There are two ways of installing the roof air conditioner:
•
Making a new opening (chapter “Making a new opening” on page 12). In this
case the opening must be reinforced by an appropriate frame.
•
Using the existing roof hatch openings (ventilation hatch) in the vehicle (chapter
“Installing in a roof hatch opening already provided” on page 13).
FreshJet-ADB2015-I-AU.book Seite 11 Freitag, 26. Januar 2018 9:23 09