Laying the connecting cables
D
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see chapter “Technical data” on page 21).
➤
Select the cross-section of the cable corresponding to the length:
–
Length < 7.5 m: 1.5 mm²
–
Length > 7.5 m: 2.5 mm²
See fig.
9
➤
Make an opening on one side in order to feed through the electrical power
supply cable.
➤
Feed the 230 V
w
cable through the opening into the vehicle interior.
If the lighting should be switched on without the use of a 230 V
w
voltage supply:
➤
Connect the cable with the positive terminal and the negative terminal of the
vehicle battery.
➤
Feed the 12 V
g
cable through the opening into the vehicle interior.
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!