EN
FreshJet
Installation
17
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
➤
Disconnect the 2-pin plug (
3
) from the socket on the circuit board of the air outlet
unit.
➤
Connect the two cables of the remote light switch to the 2-pin plug (
3
).
➤
Insert the 2-pin plug (
3
) into socket on the circuit board.
12 V
g
cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 V
w
voltage supply is not connected.
To do this, proceed as follows:
➤
Disconnect the 2-pin plug (
4
) from the socket on the main board.
➤
Connect the positive cable (
5
) with the plug.
➤
Connect the negative cable (
6
) with the plug.
Connecting the circuit board
See fig.
e
➤
Insert the 12-pin plug (
1
) in the socket (
4
) on the circuit board of the air outlet unit.
➤
Insert the two 2-pin plugs (
2
) in the sockets (
3
) on the circuit board.
7.6
Installing the air outlet unit Chillout ADB
See fig.
f
➤
Attach the air outlet unit to the (
1
) fastening frame using the short fastening
screws.
See fig.
g
➤
Install the air filter in the specified sequence.
See fig.
h
➤
Fit the filter covers.
➤
Enter the new vehicle height and weight in the vehicle documents.
FreshJet-ADB2015-I-AU.book Seite 17 Freitag, 26. Januar 2018 9:23 09