- Place refrigerator in upright position.
- Fold the thermostat capillary onto the generatrix of the evaporator tube and
secure with insulation tape so that the end of the capillary is 150 mm from
the end of the evaporator tube.
- Reinsert cooling flange
(see 2.4.1).
- Push thermostat switch back onto the shaft of thermostat. When
positioning, make sure that the shaft jointing fits with the switch bore
jointing.
(Figure 125)
- Make sure that the thermostat can be turned within the entire control
range.
- Adjust the capillary spiral that remains outside of thermostat so that it does
not overhang from the outline of the cabinet.
- Seal the point of exit of capillary from the cabinet with rubber insulator.
- Check electrical insulation resistance according to
2.3.3
.
3.2.4. Replacing timer
- Remove timer cover.
(Figure 126)
- Remove wire clamp, push down electrical wire.
(Figure 127)
- Unscrew screws securing timer.
(Figure 128)
Figure125
Figure126
Figure127
Figure128