EN
DC-Kit1
Using the DC kit
13
8.1
Switching on the system
Observe the following instructions before you switch on the system:
•
Air the vehicle.
•
Make sure that the ventilation slots on the air nozzles and the fan of the
components are not covered up.
•
Make sure that all the housings and cables are not damaged and that all the
insulation is intact.
•
Compare the existing supply voltage with the technical data.
•
Do not insert any fingers or objects into component openings.
Stationary mode: 230 V
w
mains operation
The system is supplied with 230 V
w
from the mains. Leave the inverter switched off.
The socket on the inverter supplies electricity
Driving mode: power supply from the 12 V battery
➤
Switch on the inverter using the remote control.
➤
Use the roof air conditioner as described in the operating manual.
Driving mode: power supply from the 12 V battery with motor
switched off
If the inverter switches off due to low voltage in the supply battery (10.5 V), no
voltage will be supplied to the socket and the roof air conditioner switches off. The
inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's activation point,
the socket is supplied with voltage again.
You have to switch on the roof air conditioner again manually, as the control
electronics need to be reactivated after a lack of voltage.
DC-Kit1--IO-16s.book Seite 13 Dienstag, 21. März 2017 2:05 14