EN
DC-Kit1
Installing and connecting the DC kit
11
7.2
Installing components
➤
Install the ECL-76 charging current distributor.
➤
Install the PP1002 inverter.
D
7.3
Connecting the CA1000 Dometic roof air conditioner
➤
Remove the air outlet of the roof air conditioner (
CA1000) (fig.
1
, page 2).
➤
Insert the on/off cable for CA1000 into the socket on the control board of the
roof air conditioner (fig.
3
1, page 3).
➤
Lay the on/off cable of the roof air conditioner to the ECL-76 charging current
distributor.
➤
Connect the on/off cable with connections I2 and I3 of the charging current
distributor (
ECL-76) (fig.
4
, page 3).
➤
Attach the air outlet of the roof air conditioner (
CA1000) (fig.
1
, page 2).
7.4
Connecting the FJ1100 Dometic roof air conditioner
➤
Remove the air outlet of the roof air conditioner (
FJ1100) (fig.
5
, page 4).
➤
Insert the adapting cable for FJ1100 into the socket on the control board of the
roof air conditioner (fig.
6
, page 4).
➤
Lay the on/off cable of the roof air conditioner to the ECL-76 charging current
distributor.
➤
Connect the on/off cable with connections I4 and I2 of the charging current
distributor (
ECL-76) (fig.
4
, page 3).
➤
Connecting the inverter adapter (
inverter adapter).
➤
Attach the air outlet of the roof air conditioner (
FJ1100) (fig.
5
, page 4).
DANGER! Electrocution!
Only connect the battery once you have the completed all the installa-
tion work and you are certain it has been done properly.
DC-Kit1--IO-16s.book Seite 11 Dienstag, 21. März 2017 2:05 14