ENiQ® Wall Readers & Terminals
_____________________________________________________________________________________
22
Connection ENiQ AccessManager® HiSec & ENiQ
AccessManager® Terminal HiSec
ENiQ AccessManager®/Terminal HiSec
ENiQ® Passive Reader
Fig. 10: Wiring diagram for ENiQ AccessManager®/Terminal and one ENiQ
®
Passive
Reader (HiSec) via RS485
Actuators (door openers, etc.) are controlled by the DOM ENiQ
®
Access
Manager/Terminal by means of a potential-free relay changeover contact. One
potential-free opener contact (C-Ö) and one potential-free closer contact (C-S) are
available.
You can connect potential-free switches or buttons to the inputs. These inputs
must be occupied according to the stored configuration. The standard
configuration is factory-set. Input IN1 is the door contact (opener) and input IN2
the release button (closer).
Please note! Note the maximum cable resistance and the maximum
cable length specified on the technical data sheet.
Caution! For design reasons we have had to change the connections of
the
ENiQ AccessManager®s/Terminal compared to the ELS
®
AccessManager.