DOLD MK 9063N Translation Of The Original Instructions Download Page 4

4

11.01.21 en / 335A

Ta

AC/DC

Rel2

Rel1

Esc 3s

Esc (Break) 3s

Break
(cancel changes)

OK-
(return with new settings)

(OK) 3s

Start up delay

Measuring principle

AC or DC

Input-mode

Display (Run) -

mode

Response value for Rel2

<I

RUN

I

AC [V]

DC [V]

M11491

Response value for Rel1

<I

>I

>I

Hysteresis

Hysteresis

A/R

A/R

Sp1

Sp2

t 1

v

t 2

v

After connecting the auxiliary supply A1/A2 the unit is in 

display (Run) 

mode:

The actual measured value is displayed continuously  (AC or DC)
The display is inverted when a measured value is exceeds the settings..

With button 

 the fault memory is reset. 

Pressing button 

Esc

 for more than 3 sec the unit changes to 

input mode.

In input mode the measurement is disabled, the relays are in failure mode 
and the indicator LED is orange.

With the buttons 

 

 the different setting values can be chosen.

Move cursor position

  

One character to the right 

Esc

 

One character to the left

Back to the Display (Run)-Mode

Press button 

 3 s 

OK 

New values stored

or

Press button 

Esc

 3 s; 

Break    Values unchanged 

  

RUN

 on the display confirm with  

 to change to display (Run) mode.

Display (Run) - Modus

Input-Mode

Display inverted when the actual value is in failure state.

Measurement interrupted, relays are in failure state, 
indicator LED orange color

 

  No function 

 

  Chose Rel1, Rel2, T

a

 , AC/DC and RUN   

 

  Chose parameter   

                Change and set response values for Rel1 and Rel2.

Reset fault memory: 

Input places-switch:      

Esc

    Shift cursor to the left

                                     

     Shift cursor to the right 

Esc

 For more the 3 sec, change to input mode

 For more than 3 sec, change to display mode

Operating

Summary of Contents for MK 9063N

Page 1: ... 2 relay outputs The current monitoring can be assigned ro relay 1 and or relay 2 Circuit Diagrams MK 9063N 11 MH 9063 12 Example overcurrent monitoring with de energized on trip t t t ta tv M10935 I Hyst 11 14 I UH 21 11 A1 k 22 12 24 14 A2 M10936_c 11 12 14 21 22 24 i i k 11 A1 12 A2 14 M10937_a 11 12 14 The current relays MK 9063N and MH 9063 of the varimeter family provide a solution for an op...

Page 2: ...es Pressing Esc for more than 3 sec starts the input mode If the setting value is exceeded the relay switches and the display indica tes this state The display is inverted flashes and shows the error The fault memory is selectable With button the fault memory can be deleted On the unit MH 9063 it is possible to assign different functions to the diffe rent relays so one can be used as pre warning a...

Page 3: ...e corresponding relay output switches after the selected time delay tv and the fault is indicated on the display Manual reset can be activated or de activated and is operated with on the unit Limit values for Rel 1 and Rel 2 Selectable with buttons Factory setting I Response value undercurrent Undercurrent relay OFF I Response value overcurrent Overcurrent relay Hyst Response value hysteresis 5 tv...

Page 4: ...nt is disabled the relays are in failure mode and the indicator LED is orange With the buttons the different setting values can be chosen Move cursor position One character to the right Esc One character to the left Back to the Display Run Mode Press button 3 s OK New values stored or Press button Esc 3 s Break Values unchanged RUN on the display confirm with to change to display Run mode Display ...

Page 5: ... kV 2 Measuring input contacts 6 kV 2 Contacts 11 12 14 21 22 24 4 kV 2 EMC Electrostatic discharge ESD 8 kV air IEC EN 61000 4 2 HF irradiation 80 MHz 2 7 GHz 20 V m IEC EN 61000 4 3 Damped oscillatory wave immunity test Differential mode voltage 1 kV IEC EN 61000 4 18 Common mode voltage 2 5 kV IEC EN 61000 4 18 Fast transients 2 kV IEC EN 61000 4 4 Surge voltage Between wires for power supply 1...

Page 6: ...o the right and left 4 Please note that the terminal blocks have to be mounted on the belonging plug in terminations Screw terminal PS plugin screw Cage clamp terminal PC plugin cage clamp Options with Pluggable Terminal Blocks Notes Set Up Procedure Safety Notes MK 9063N 11 AC DC 0 4 10 A DC 24 V Article number 0065457 Measuring range AC DC 0 4 10 A Auxiliary voltage UH DC 24 V Output 1 changeove...