DOLD BG 5914.08 0 Series Operating Instructions Manual Download Page 5

5

BG 5914.08/_0_ _ _, BH 5914.08/_0_ _ _ / 03.11.20 / 314A

The product hereby described was developed to perform safety functions 
as a part of a whole installation or machine. A complete safety system 
normally includes sensors, evaluation units, signals and logical modules 
for safe disconnections. The manufacturer of the installation or machine 
is responsible for ensuring proper functioning of the whole system. DOLD  
cannot guarantee all the specifications of an installation or machine that 
was not designed by DOLD. The total concept of the control system into 
which the device is integrated must be validated by the user. DOLD also 
takes over no liability for recommendations which are given or implied in 
the following description. The following description implies no modification 
of the general DOLD terms of delivery, warranty or liability claims.

 

Safety Regulations

 

- This device must be installed and operated by trained staff who are  
  familiar with these instructions and with the current regulations for safety  
  at work and accident prevention.

 

- Pay attention to applicable local regulations, especially regarding safety  
 measures.

 

- Opening the device or implementing unauthorized changes voids any  
 warranty

 

- The unit should be panel mounted in an enclosure rated at IP 54 or  
  superior. Dust and dampness may lead to malfunction.

 

- Adequate fuse protection must be provided on all output contacts with  
  capacitive and inductive loads.

 

- The safety function must be triggered during commissioning

The input module BG 5914 or BH 5914 can only be used with the control unit 
BH 5911. It can extend the number of 2-channels safety inputs up to 13. The 
Multi-Function Safety System is used to enable and interrupt a safety circuit 
in a safe way. It can be used to protect people and machines in applicati-
ons with e-stop buttons, safety gates, light curtains with selftesting (Type 
4) acc. to IEC/EN 61 496-1, 2-hand controls for presses as well as other 
production machinery with dangerous closing action (Type III A or III C to  
EN 574). When used in accordance with its intended purpose and following 
these operating instructions, this device presents no known residual risks. 
Nonobservance may lead to personal injuries and damages to property.

•  According to

 

-

Performance Level (PL) d and category 2 to EN ISO 13849-1: 2008

 

-

SIL Claimed Level (SIL CL) 2 to IEC/EN 62061 

 

-

Safety Integrity Level (SIL 2) to IEC/EN 61508

  Input module for realization of:

 

- 8 E-STOP, single-channel, autostart

 

- 6 E-STOP, single-channel, + 1 E-STOP, 2-channel, autostart

 

- 5 E-STOP, single-channel, + 1 -STOP,  2-c 1 signal input,  

 autostart

 

- 8 E-STOP, single-channel, manual start

 

- 6 E-STOP, single-channel, + 1 E-STOP,  2-channel, manual start

 

- 5 E-STOP, single-channel, + 1 E-STOP,  2-c 1 signal input,  

  manual start

 

- As an alternative to the 2-channel E-STOP, a light curtain (LC type 4)  

  according to EN 61496-1 can be connected.

•  Broken wire and short circuit monitoring function with error indication

•  2 semiconductor outputs per function module for status indication

•  LEDs for status indication

•  Width: 22.5 mm (BG 5914) or 45 mm (BH 5914)

0272145

Realization of fail-safe control circuits for protection of people and machinery
The modules BG 5914 and BH 5914 have been developed for applica-
tions in which numerous one-channel Emergency stop contacts have to 
be monitored.

Green LEDs: 

on, when all inputs are present and start  

 

 

button activated.

White LEDs Run1/
Run 2 and outputs
48 and 58: 

 indicate the current status of the module.

Terminal designation

Signal designation

(-)

Reference potential for 

inputs and outputs

X1, X2

Control outputs

S12, S14, S22, S24

S32, S34, S42, S44

Control inputs

S11, S13, S21, S23

S31, S33, S41, S43

Reference potential for 

galvanic separation control inputs

(only at BH 5914)

Before installing, operating or maintaining this device, these instructions 
must be carefully read and understood.

Operating instructions                   ENGLISH

Multi-Function Safety System SAFEMASTER M 
Input Module 
BG 5914.08/_0_ _ _, BH 5914.08/_0_ _ _

Translation 

of the original instructions

 

CAUTION

Safe operation of the device is only guaranteed when using certified 
components!

 

DANGER

Dangerous voltage.
Electric shock will result in death or serious injury.

Disconnect all power supplies before servicing equipment.

Important Notes

Designated Use

    

Safety Notes

ATTENTION - AUTOMATIC START!

According to IEC/EN 60 204-1 part 9.2.5.4.2 and 10.8.3 it is not allowed to 
restart automatically after emergency stop. Therefore the machine control 
has to disable the automatic start after emergency stop.

Connection Terminals

Indication

The maximum configuration of the SAFEMASTER M multi-function safety 

system is as follows:

•  the control unit BH 5911

•  up to 3 input modules BG/BH 5913, or BG/BH 5914, BG/BH 5915

•  up to 3 output modules BG 5912

•  1 diagnostic module BG 5551 for CANopen, or

•  1 diagnostic module BG 5552 for Profibus-DP

The BH 5911 controls the whole system.

The input/output modules can be used to expand the control unit in a 

modular way into a multi-functional safety system.

To transmit status messages of the individual modules to a moni to ring or 

control unit, one of the following diagnostic modules may be connected: 

•  BG 5551 for CANopen

•  BH 5552 for Profibus-DP

General Information SAFEMASTER M

Applications

Main Features

All technical data in this list relate to the state at the moment of edition. We reserve the right for 
technical improvements and changes at any time.

Summary of Contents for BG 5914.08 0 Series

Page 1: ...OT AUS 1 kanalig 1 NOT AUS 2 kanalig Auto Start 5 NOT AUS 1 kanalig 1 NOT AUS 2 kanalig 1Meldeeingang Auto Start 8 NOT AUS 1 kanalig manueller Start 6 NOT AUS 1 kanalig 1 NOT AUS 2 kanalig manueller S...

Page 2: ...astern T1 T4 und den Sicher heitsausg ngen Relais erfolgt ber DIP Schalter Die Einstellung der Funktionskombination erfolgt ber die Drehschalter Potis Um Manipu lationen auszuschlie en sind die Einste...

Page 3: ...en oder beim Auftreten eines Fehlers bet tigt 5 Eingangsfehler Kurzschluss Unterbrechung 6 Fehler in der Steuereinheit Eingangs oder Ausgangsfehler in der Steuereinheit erkannt Anzahl von kurzen Blink...

Page 4: ...zwischen den Modulen ein Abstand von ca 3 5 mm einge halten werden Luft und Kriechstrecken Bemessungssto spannung Verschmutzungsgrad 4 kV 2 Basisisolierung IEC 60 664 1 EMV IEC EN 61 326 3 1 IEC EN 6...

Page 5: ...nual start 6 E STOP single channel 1 E STOP 2 channel manual start 5 E STOP single channel 1 E STOP 2 channel 1 signal input manual start As an alternative to the 2 channel E STOP a light curtain LC t...

Page 6: ...nd BH 5914 are completely identical The modules are assigned to the start buttons and the safety outputs via the DIP switches The function is set via the rotary switches To prevent accidently adjust m...

Page 7: ...error recognized in the con trol unit number of short flashing impulses followed by a longer space Permanently OFF Pulsing Permanent ON Output 48 all relays inactive due to system error one input func...

Page 8: ...mperature range 0 50 C At an operating temperature of 50 C the modules must be mounted with a distance of 3 5 mm Clearance and creepage distances rated impulse voltage pollution degree 4 kV 2 basis in...

Page 9: ...A U 1 canal 1 A U 2 canaux avec d marrage auto 5 A U 1 canal 1 A U 2 canaux 1 entr e de signalisation avec d marrage auto 8 A U 1 canal avec d marrage manuel 6 A U 1 canal 1 A U 2 canaux avec d marrag...

Page 10: ...de 45 mm L affectation de l unit centrale aux boutons start T1 T4 et aux sorties de s curit relais s effectue par interrupteurs DIP Le r glage de la fonction s effectue au moyen de potentiom tres Pour...

Page 11: ...ies de s curit correspondantes est autoris e DEL run 1 Tous relais inactifs suite d faut syst me D faut de fonct quand DEL run 2 allum e ou d faut syst me quand DEL run 2 tein ou clignote L activation...

Page 12: ...mp ratures 0 50 C Pour une temp rature de service de 50 une distance de 3 5 mm entre les modules doit tre respect e Distances dans l air et lignes de fuite Cat gorie de surtension degr de contaminatio...

Page 13: ...unctions 1 or 5 FR BG 5914 6 A U 1 canal 1 A U 2 canaux avec d tection de court circuit fonctions 1 5 DE Anwendungsbeispiele EN Application examples FR Exemples d utilisation X1 X2 S12 S14 S22 S24 S32...

Page 14: ...R BG 5914 5 arr t d urgence 1 canal 1 EPES de type 4 1 contact de signalisation interrupteurs gradins 3 et 7 DE Anwendungsbeispiele EN Application examples FR Exemples d utilisation X1 X2 S12 S14 S22...

Page 15: ...7 FR BH 5914 5 A U 1 canal 1 A U commun 2 canaux avec d tection de court circuit par c blage 1 contact de signalisation interrupteurs gradins 3 7 DE Anwendungsbeispiele EN Application examples FR Exe...

Page 16: ...1 48 X1 58 X2 X1 X2 X1 X2 X2 M8742 S11 S31 S14 S34 S21 X1 X2 X1 X2 X1 X2 X1 X2 S41 S22 S42 S23 S43 S24 S44 S12 S32 S13 S33 48 58 A1 A1 X1 S44 S42 S34 S32 S24 S22 S14 S12 X2 48 58 input module PTC inpu...

Page 17: ...Dimensions dimensions en mm M10050 45 Hutschiene DIN EN 60715 121 118 84 35 DE Montage Demontage der Klemmenbl cke EN Mounting disassembly of the terminal blocks FR D montage des borniers ammovibles D...

Page 18: ...HD 3 53E 09 h 1 HFT Hardware Fehlertoleranz Hardware failure tolerance Tol rance d fauts Hardware Anforderung seitens der Sicherheitsfunktion an das Ger t Intervall f r zyklische berpr fung der Sicher...

Page 19: ...multifonctions Produktbezeichnung Type designation D signation du produit Beschreibung Description Description BH5911 03 00MF0 DC24V Steuereinheit Control Unit Unit centrale BH5911 22 00MF0 DC24V BG59...

Page 20: ...BG 5914 08 _0_ _ _ BH 5914 08 _0_ _ _ 03 11 20 314A E DOLD S HNE KG D 78120 Furtwangen e mail dold relays dold com internet http www dold com Bregstra e 18 Telefon 0 77 23 654 0 Telefax 0 77 23 654 3...

Reviews: