Double Checking the System & Future Troubleshooting
1. The
GREEN
power light should be on when the transmitter is plugged in.
2. The
RED
indicator light is on when the loop wire is intact. If the
RED
light is
off, but the
GREEN
light is on, check for places where the wire loop might be
interrupted. Here are some things you can check if this occurs:
•
Are the twisted pair ends of the wire correctly attached to the transmitter?
•
Has any buried wire been exposed or damaged due to root or rodent damage?
•
Are the direct burial splices properly connected?
3. Leave the power switch on unless the transmitter is not going to be used for an
extended period, or you are experiencing a thunderstorm.
4. The battery in the receiver should be placed (+) side up.
5.
The
YELLOW
fault light will come on if the transmitter is damaged by
lightning or power surges, or if an internal part fails.
6.
Has the ground wire been connected from the transmitter to the outlet plate or
grounding rod?
The Dog Guard System – DG9000 and Transmitter “You can’t see a better way to protect your pet!”