![Doco DOCOMATIC 1200 Installation Manual Download Page 7](http://html.mh-extra.com/html/doco/docomatic-1200/docomatic-1200_installation-manual_2514928007.webp)
38
2
+24V
-0V
+24V
-0V
NC
NO
COM
1
2
1
2
3
4
5
F1
On-site installation and any work on 230 V may only be carried out by qualified and skilled electricians. The con-
nections for the signal, external lighting, mains, transformer (11-22) and the screw terminals for the connection
of the signal module carry 230V!
Only potential-free (= zero voltage) connections may be made at the START (1, 2) and EMERGENCY (3, 4). If the
EMERGENCY connection (3, 4) is not used, the terminals must be connected with a jumper (condition at the time of
delivery).
Only non-latching contacts (e.g. push buttons) may be connected to START (1, 2) and never self-holding or latching
contacts (e.g. switch). Self-holding contacts generate a continuous signal and therefore they block all other func-
tions.
Control board B 300.01-OKP
Wireless receiver on the plug-in socket "Molex" (B 300.01-OKP)
Motor
24 V/DC
Transformer
Secondary
Earth base
plate
Start
command
Light barrier for receiver
(B210.090)
Light barrier for
transmitter(B210.090)
Motor
Sensor cable
LED green
LED red
Transformer
Primary
Mains power
supply
Lamp
Emergency
Off
Flap door
External lighting
230 V AC max. 60 W
Green signal
230 V AC max. 60 W
Red signal
230 V AC max. 60 W
Signal module
B 300.04
DOCO
MATIC
7/23
04-10
Summary of Contents for DOCOMATIC 1200
Page 2: ...1 2 3 4 5 6 8 7 Ø3 Ø10 Ø5 6 10 13 17 a b e c d 1 2 3 4 Motor a DOCOMATIC 2 23 04 10 ...
Page 3: ...10 13 14 15 16 11 12 9 a b d c b a a b c 0 5 cm 0 5 cm DOCOMATIC 3 23 04 10 ...
Page 4: ...18 21 22 23 24 19 17 20 a Ø10 c Ø10 b 90 5 7cm max 30 DOCOMATIC 4 23 04 10 ...
Page 5: ...26 29 30 31 32 27 25 28 2x 4x a b Ø5 b 1 2 a Ø3 a b DOCOMATIC 5 23 04 10 ...