4.5 Signal module
Using the optional signal module B 300.04, red and green signal lamps of up to max. 60 W respectively can be connected
to the 230 V supply.
FUNCTION:
While opening, the red signal lights up or starts flashing after input of the start impulse (setting via menu, see 3.5 / b: binary
add-on functions / POINT 6 or brief instructions on page 8).
After expiry of the lead time that can be set in various steps of 0 -12 sec. (menu H, see 3.5 / H: Lead time for the signal or
brief instructions on page 8) the door starts moving and the red signal lamp lights up permanently. If the door is open, the
red signal lamp goes off and the green signal lamp lights up.
While closing, the green signal lamp goes off once the start impulse is input and the red signal lamp lights up or begins to
flash. After the lead time has elapsed the door begins to move and the signal changes to continuous red light. The red signal
lamp goes off once the door is closed.
ATTENTION - DANGER TO LIFE! The screw fasteners of the signal module are also used to feed the power supply to
the signal connection; they carry 230 V AC! Ensure that the drive has been unplugged from the mains supply when
any work is being done, and prevent it from being plugged in!
INSTALLATION:
• (FIG. 28) Disconnect the power supply to the drive (remove the plug) and take off the light cover.
• (FIG. 30/31) Unscrew the hood and remove it.
• (FIG. 32) Remove the caps of the screw fasteners, place the signal module and fasten it with screws, and put on the caps
again.
• Fasten and tighten the hood with the screws, and then you can connect the signal to the terminals of the signal module.
Please use cable cores having min. 0.75mm² up to a maximum length of 20 m.
• Put the light cover back in place and fasten it.
After installing the signal module, the warning lamp connection (terminals 9/10) works automatically as a door sta-
tus indication (see 4.6), since the warning or flashing feature must be implemented via the red signal lamp.
The potential-free connection for warning lamp / door status indication must be protected externally with a fuse
rating of max. 1A, in order to rule out any damage to the controller. The maximum contact load-bearing capacity
is 1A on 230 V AC or 30 V DC.
Use suitable cable for the connection of the door status indication or warning lamp in keeping with the voltage / load used.
We recommend that the warning lamp be installed at a point that is exposed as far as possible and, above all, can be seen
easily from all positions at risk from the door movement.
Door status indication:
As a rule, if the signal module is installed (see 4.5), the connection at terminals 9/10 acts as the door status indication; it ge-
nerates a continuous signal when the status is "Door closed", which can be wired with any desired application. The same is
true when the signal module is not plugged in and when the automatic door close feature is disabled (inactive) (see 3.5 /
binary add-on functions / POINT 3).
Warning lamp:
When the signal module is not plugged in (see 4.5) but the automatic door close feature is enabled (active) (see 3.5 / b:
binary add-on functions / POINT 3) the connection at terminals 9/10 works, in general, as a warning lamp connection.
You have the option of connecting a warning lamp (without integrated flashing control electronics) or a flashing lamp (with
integrated flashing control electronics). You can make this selection in the menu (see 3.5 / b: binary add-on functions /
POINT 6 or brief instructions on page 8).
The lead time can be configured in the menu from 0 - 12 sec. (see 3.5 / U: Lead time for warning lamp or brief instructions
on page 8).
4.7 External lighting
ATTENTION - DANGER TO LIFE! Terminals 15/16 for the external lighting carry 230 V AC! Ensure that the drive has been
unplugged from the mains supply when any work is being done and prevent it from being plugged in!
An external supplementary lamp of 230 V AC up to max. 60 W or a switching relay can be connected directly to terminals
15/16/17. The connection is held live for the same period of time as that of the lighting of the drive-internal illumination
and can be set in various steps (see 3.5 / L: lighting period or brief instructions on page 8). We recommend
the use of cable cores having a cross-section of at least 0.75mm² up to a total length of max. 20 m.
DOCOMATIC 18/23 04-10
4.6 Warnleuchte/Torzustandsmeldung
DOCO
MATIC
18/23
04-10
Summary of Contents for DOCOMATIC 1200
Page 2: ...1 2 3 4 5 6 8 7 Ø3 Ø10 Ø5 6 10 13 17 a b e c d 1 2 3 4 Motor a DOCOMATIC 2 23 04 10 ...
Page 3: ...10 13 14 15 16 11 12 9 a b d c b a a b c 0 5 cm 0 5 cm DOCOMATIC 3 23 04 10 ...
Page 4: ...18 21 22 23 24 19 17 20 a Ø10 c Ø10 b 90 5 7cm max 30 DOCOMATIC 4 23 04 10 ...
Page 5: ...26 29 30 31 32 27 25 28 2x 4x a b Ø5 b 1 2 a Ø3 a b DOCOMATIC 5 23 04 10 ...