CE-Conformity 

 

This assembly is controlled by a microprocessor and uses high 
frequency. In order to maintain the properties of the module with 
regard to CE conformity, installation into a closed metal housing in 
accordance with the EMC directive 2014/30/EU is necessary. 
 

 

Risk-Notes 

 
You purchased a technical product. Conformable to the best available technology the 
following risks should not excluded: 

 

 

Failure risk:

 The device can drop out partially or completely at any time without 

warning. To reduce the probability of a failure a redundant system structure is 
necessary. 
 

Initiation risk:

  For the installation of the board, the board must be connected and 

adjusted to foreign components according to the device paperwork. This work can 
only be done by qualified personnel, which read the full device paperwork and 
understand it. 
 

Operating risk:

 The Change or the operation under special conditions of the 

installed systems/components could as well as hidden defects cause to breakdown 
within the running time. 
 

Misusage risk:

 Any nonstandard use could cause incalculable risks and is not 

allowed. 
 

Warning: 

It is not allowed to use the device in an operation, where the safety of 

persons depend on this device. 
 
 

Disposal 
 

Electronical and electronic products must not be disposed in 
domestic waste. Dispose the product at the end of its service life 
in accordance with applicable legal regulations. 
Information on this can be obtained from your local waste  
disposal company.  

 

 

ArtNet

 is a trade mark of Alderamin Group Ltd.  Designed by and Copyright Artistic Licence Holdings 

Ltd. 

 

 

Summary of Contents for ArtNet-DMX TWIN PoE

Page 1: ...ArtNet DMX TWIN PoE User manual...

Page 2: ...DMX TWIN PoE is disengageable via ArtNet Command AcLedMute or time controllable This is very helpful on stages to avoid disturbing light points Easy Configuration A user friendly Configuration via a w...

Page 3: ...E according to IEEE 802 af or included 5V DC Power supply Ethernet RJ45 DMX 2x 3 pin screw connector Separated adjustable 512 Channels OUT 512 Channels IN DMX Framerate Adjustable Protocol Art Net or...

Page 4: ...ArtNet DMX TWIN PoE 4 Connection 2x DMX In Output 1 GND 2 DMX 3 DMX USB POWER 5V ETHERNET USB LED PoE LED PORT1 LED PORT2 LED...

Page 5: ...ed for transferring data with the ArtNet DMX TWIN PoE PORT1 PORT2 LED The PORT LED lights up as soon as the DMX Data are outputted or received at the port The PORT LED flashes if the port puts no DMX...

Page 6: ...ator allows the IP Address and net mask setting also if the net work settings of the PC are not within the IP Range of the ArtNet DMX TWIN PoE Install the program IP Configurator Connect the ArtNet DM...

Page 7: ...which can be used for the Web Interface Please adjust the net work card from the PC to this IP Range to call the web browser via IP Address 2 0 0 10 The computers net work setting must be adjusted to...

Page 8: ...5 0 You can assign each node with any name for a better distinction The Short Name is limited up to 18 signs and the Long Name up to 64 signs The ArtNet Parameter SubNet Net and Port are to set accord...

Page 9: ...available HOLD last data All channels are leaved unchanged CLEAR all to 0 All DMX Input channels will be set to 0 SET all to 100 All DMX Input channels will be set to 255 NO OUTPUT No DMX Signal is o...

Page 10: ...case of a DMX Signals failure DMX IN FAIL NO DATA No DMX Input is received via ArtNet HOLD last DMX data The latest data are maintained CLEAR all DMX channels to 0 All DMX Channels are set to 0 SET a...

Page 11: ...4ALL Commands the separated DMX4ALL Command description VCP Controlling For controlling via a COM Port a TCP VCP Program must be installed which provides a virtual Com Port VCP We recommend the tool S...

Page 12: ...ArtNet DMX TWIN PoE 12 Finally click Update all in the main window to activate the VCP Now the status Available and COM Port are shown within the device manager...

Page 13: ...7319 Click Send Please wait then minimum 10 seconds Alternatively you can restore the default conditions with DMX4ALL LAN Updater Turn off the device Start the software DMX4ALL LAN Updater Create a c...

Page 14: ...r Select ArtNet DMX TWIN PoE in the list Click Firmware Update Select and confirm Firmware File bin Please wait until the Update is ready If an error occurs during the Update you can start from beginn...

Page 15: ...ign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation und...

Page 16: ...d using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely It is pointed out that...

Reviews: