Digital Monitoring Products, Inc | 7000 Series Installation and Programming Guide
8
WIRE THE KEYPAD
Each keypad model has specific wiring assignments. All zones are supervised. Use
1k Ohm EOL resistors, DMP Model 311 on keypad zones 1-4. Locate the keypad model
below and refer to Figure 5 to wire the keypad.
Models 7060/A, 7063/A, 7160, and 7163
Supplied with a 4-wire harness for panel keypad bus connection.
Models 7070/A, 7073/A, 7170, and 7173
Supplied with a 12-wire data bus/zone harness. Four wires connect to the keypad bus.
The remaining eight wires are for the four zone inputs, four wires for each zone.
Models 7073/A and 7173
Supplied with a 5-wire output/reader harness and a 12-wire data bus/zone harness.
Firmly grasp the wires near the base and hold the outside
edges of the keypad housing. Line up the red and yellow
wires with the guides on the board to inset the connector
into the J5 keypad terminal. Observe wire colors when
connecting the red, yellow, green, and black wires to the
keypad bus. See Figure 4.
• Connect red wire to panel terminal 7
• Connect yellow wire to panel terminal 8
• Connect green wire to panel terminal 9
• Connect black wire to panel terminal 10
2
Figure 4: Wiring Harness
J5
Y/W
R