7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
5
PANIC KEY OPTIONS
2-Button Panic Keys
All keypads offer a panic key function that allows users to send panic, emergency, or fire
reports to the central station in an emergency. Enable the panic key function in the keypad
user menu. Place the supplied icon stickers below the top row select keys. The user must
press and hold the two select keys for two seconds until a beep is heard.
Panic
(left two select keys)—Zone 19 + Device Address
Emergency Non-Medical
(center two select keys)—Zone 29 + Device Address
Fire
(right two select keys)—Zone 39 + Device Address
7/0 Panic Keys
All keypads allow the user to initiate a panic alarm by pressing the 7 and 0 (zero) keys at
the same time for one-half (1/2) second. Enable the 7/0 Panic function in Installer Options.
When enabled, all keypads send a Zone Short message to the panel for the first zone of
the keypad address. When the keys are released, a Zone Restore message can be sent
from the initiating keypad. To produce a panic alarm, program the first zone of the keypad
address as a panic type (PN) in panel programming. Place a 1k Ohm end-of-line (EOL)
resistor, DMP Model 311, across the white/brown pair of zone wires on models 7070/A,
7073/A, 7170, and 7173. A Zone Restore message sends when the keys are released. The 1k
Ohm EOL resistor is not required on 7060/A, 7063/A, 7160, and 7163 keypads.