7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
17
Keypad Mode
Keypads with programmed zones must be supervised and
cannot share an address with other keypads. Unsupervised
keypads can operate together sharing the same address, but
cannot be used when Device Fail Output has a programmed
value other than zero. To select a keypad mode, press the
select key under
SUP
or
UNSUP
. An asterisk appears next to
the selected option.
Default Keypad Message
Enter a custom message of up to 16 characters to appear at
the top of the keypad display. Press any select key, enter a
new message, and press
CMD
.
Arm Panic Keys
Use this option to configure the select keys as two-button
panic keys. To enable or disable a panic option, press
the select key under the desired name:
PN
(panic),
EM
(emergency), and
FI
(fire). Press the select key again to
disable the panic option. Once the panic option is enabled,
an asterisk displays next to the selected option(s).
7/0 Panic
Press the fourth select key to choose
YES
, configuring the
7 and 0 keys as two-button panic keys. Select
NO
to disable
the option. Default is
NO
.
KEYPAD MODE:
*SUP
UNSUP
DEFAULT KPD MSG:
ARM PANIC KEYS:
*PN EM *FI
7/0 PANIC
ENABLE:
NO