Series Universal Communicator Installation and Programming Guide 

Digital Monitoring Products

11

Communication

7.1 

Communication

The Communication section allows you to configure the communication settings for the 

iComSL

 

Communicator. After choosing the Communication Type, continue through the 

list of options.

7.2 

Account Number

Enter the account num ber sent to the receiver.

The range of account numbers is 1 to 65535. For account numbers of four digits or less, 

you do not have to enter leading zeros. The c

ommunicator automatically right justifies 

the account number.

7.3 

Transmission Delay

 Enter the number of seconds (15 to 45 seconds) the 

communicator waits before sending 

burglary alarm reports to the receiver. Enter 0 (zero) to disable this function. The 

default is 0.

7.4 

Communication Type

 The  c

ommunicator uses Network communication to DMP Model SCS-1R or SCS-VR 

Receivers.

7.5 

Test Time

 Press COMMAND to display the Test Time. Enter the time of day the 

communicator sends 

the test report to the SCS-1R or SCS-VR Receivers. Use entries between 12:00 to 11:59 

and then choose AM or PM.

7.6 

Test Days

Enter how often the panel test report is sent to the receiver. Enter from 1 to 60 days. 

Enter zero to disable the test report. Default is 1 (one) day. These options only display if 

a test time is entered.

7.7 

Check-in Minutes

Check-in reports are a method of supervising the panel for communication with the 

receiver.

Enter the number of minutes between check-in reports. Select from 0 or 3-240 minutes. 

Enter 0 (zero) to disable the check-in option. Default is 0.

7.8 

Fail Time

Fail Time allows the SCS-1R or SCS-VR receiver to miss a defined number of check-ins 

before logging that the panel is missing. For example, if 

NET CHECKIN 

is 20 and 

FAIL 

TIME

 is 30, the SCS-1R receiver only indicates a Panel Not Responding after 30 minutes. 

The 

FAIL TIME must be equal to or greater than the NET CHECKIN minutes: If the 

CHECKIN is 20 minutes, the 

FAIL TIME 

must be 20 or more. The maximum 

FAIL TIME is 

240 minutes. Select from 0 or 3-240 minutes. The default 

FAIL TIME 

is 240 minutes.

7.9 

Receiver 1 Programming

Allows you to set the options for the first receiver the 

communicator attempts to 

contact when sending reports. The communicator supports communication to two 

receivers.

7.10 

Alarm Reports

YES enables Alarm, Alarm Restoral, Exit Error, and System Recently Armed reports to be 

sent to this receiver. Default is YES

7.11 

Supervisory/Trouble Reports

YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, and Fault reports to be 

sent to this receiver. Default is YES.

7.12 

Opening/Closing and User Reports

YES enables Opening/Closing, Schedule and Code Changes, and Bypass reports by user to 

be sent to this receiver. Default is YES.

7.13 

Test Report

Enter YES to enable the Recall Test report to be sent to this receiver.

7.14 

 First IP Address

Enter the first (primary) IP address where the 

communicator sends messages. The IP 

address must be unique and cannot be duplicated on the network. Enter all 12 digits and 

leave out the periods. For example, enter IP address 192.168.0.250 as 192168000250. 

The periods display automatically.

7.15 

First IP Port

Enter the first IP port number to be used in conjunction with the First IP Address. The IP 

port identifies the port used to communicate messages to and from the 

communicator. 

The default IP Port setting is 2001.

COMMUNICATION

ACCOUNT NO:

XMIT DELAY:   

 0

COMM TYPE:     CELL

CELL TST DAYS: 

1

 

CHECKIN:   0

FAIL TIME:    

240

RECEIVER 1 PROG

ALARM NO 

YES

SPV/TRBL NO YES

O/C USER  NO  YES

TEST RPT 

NO  YES

FIRST IP ADDR 

000.000.000.000

FIRST IP PORT

  

2001

TEST TIME

00:00 AM

communIcatIon

Summary of Contents for iComSL Series

Page 1: ...IComsl Series Universal Alarm Communica tor Installation and programming Guide...

Page 2: ...om the U S Government Printing Office Washington D C 20402 Stock No 004 000 00345 4 2014 Digital Monitoring Products Inc Information furnished by DMP is believed to be accurate and reliable This infor...

Page 3: ...rted 7 5 3 Programming Menu 7 5 4 Reset Timeout 7 5 5 Special Keys 8 5 6 Entering Alpha Characters 8 5 7 Entering Non Alpha Characters 9 5 8 Keypad Displays Current Programming 9 Initialization 10 6 1...

Page 4: ...t 14 8 14 SMTP Username 14 8 15 SMTP Password 14 8 16 From Email Address 14 Remote Options 15 9 1 Remote Options 15 9 2 Remote Key 15 9 3 Remote Disarm 15 System Reports 15 10 1 System Reports 15 10 2...

Page 5: ...ut Code 21 Z Wave Setup 22 17 1 Add Z Wave Devices ADD 22 17 2 List Z Wave Devices LIST 22 17 3 RENAME Z Wave Devices 22 17 4 STATUS of Z Wave Devices 23 17 5 Remove Z Wave Devices REMOVE 23 17 6 Favo...

Page 6: ...of Contents 18 5 Cross Zoning 28 18 6 Z Wave Information 28 18 7 Zone 4 Bell Cadence Information 28 Remote Arming Disarming for Ademco Vista Control Panels 29 Ademco Vista 20P to iComSL 30 DMP XRSuper...

Page 7: ...ection See Applications on page 5 The iComSLCZ Alarm Communicator includes an onboard Z Wave controller for home automation applications What is Included The iComSL Series Universal Alarm Communicator...

Page 8: ...reset the communicator again 1 6 Load Button The iComSL Series Universal Alarm Communicator software can be updated via the programming PROG header To update the communicator with a new software vers...

Page 9: ...S1 S2 S3 J9 Figure 7 Wire Routing Options R B J8 J1 RESET LOAD S1 S2 S3 J9 R B J8 J1 RESET LOAD S1 S2 S3 J9 Mounting the communicator on or near metal surfaces impairs Z Wave wireless performance The...

Page 10: ...26 J9 S1 S2 S3 1k ohm 1k ohm 1k ohm 1k ohm MODEL iComSLC Figure 9 iComSL Series Wiring Diagram for Zones 1 4 Use 18 22 AWG for Power Supply connection CONTROL PANEL TIP CONTROL PANEL RING 12 VDC Aux O...

Page 11: ...ne name to send to the Central Station Zones 5 and 6 cannot be preprogrammed in Zone Information Note CID Dialer Connection cannot be used when using Zone 4 Bell Connection Use 18 22 AWG for Power Sup...

Page 12: ...dc Aux Output Control Panel BAT MODEL iComSL PROG 12 G Z1 Z2 Z4 Z4 G Z3 R T O2 O1 R B GND Zone 1 Zone 2 Control Panel EOL resistor Figure 11 Virtual Keypad Application can be used to access the iComSL...

Page 13: ...ommunicator use the Initialization function described in Section 6 Initializing clears the communicator s memory of any old data and sets the highest numbered user number to user code 99 Accessing the...

Page 14: ...communicator memory by pressing the appropriate Select key under or on the display You then enter the new information using the keypad data entry digit keys When there are more than four re sponse opt...

Page 15: ...splays Current Programming Each programming prompt displayed at the keypad shows the currently selected option in the communicator memory These options are either shown as a number a blank or a NO or...

Page 16: ...existing zone information intact YES sets all zones in the system to UNUSED 6 6 Clear Communication NO Leaves existing communication programming intact YES Clears communication to factory defaults 6...

Page 17: ...For example if NET checkin is 20 and Fail TIME is 30 the SCS 1R receiver only indicates a Panel Not Responding after 30 minutes The Fail TIME must be equal to or greater than the NET CHECKIN minutes...

Page 18: ...t is NO 7 21 Opening Closing and User Reports YES enables Opening Closing Schedule and Code Changes and Bypass reports by user to be sent to this receiver Default is NO 7 22 Test Report YES enables th...

Page 19: ...m this account This option is used when sending commands such as arming or disarming to the iComSL using Email The user number must have the authority to perform the commands Entering 0 zero disables...

Page 20: ...that the panel uses to initiate a TCP connection with the Email server The default port is 25 8 14 SMTP Username Most SMTP servers require a username to send Email This will be sent to the SMTP serve...

Page 21: ...ystem Options 11 1 System Options This section allows you to select system wide parameters used in the operation of the communicator system A description of each System Option follows 11 2 Entry Delay...

Page 22: ...tion allows the communicator to request automatic time changes from the DMP SCS 1R or SCS VR Receiver For the receiver to send time changes it must be programmed to send time changes and must be recei...

Page 23: ...ro to disable this output 12 5 Remote Arming Output When the system is armed or disarmed remotely from the Virtual Keypad App Virtual Keypad Browser MyAccess RemoteLink or from a schedule this Output...

Page 24: ...zone name Refer to the Enter Alpha Characters section 14 3 Zone Name Press any Select key and enter up to 16 characters for the zone name A name must be given to each zone in the system The zone name...

Page 25: ...tate a trouble is reported If opened from a shorted armed state an alarm is reported and the zone is disabled until you disarm the area from either the Virtual Keypad App MyAccess Virtual Keypad Brows...

Page 26: ...ion the zone remains normal for one hour and the Reset Swinger Bypass is YES If the zone trips fewer than the specified times within one hour of the first trip the bypass trip counter returns to 0 zer...

Page 27: ...e Lockout Code You can change this code at any time to any combination of numbers from 1 to 5 digits long 1 to 65535 Do not use leading zeros for the lockout code 1 Press any Select key The display ch...

Page 28: ...e keypad displays ADD LIST REMOVE Select ADD PROCESSING may briefly display When PRESS BUTTON ON DEVICE TO ADD displays press the program button on the Z Wave device See the Z Wave device s documentat...

Page 29: ...Select REMOVE PROCESSING may briefly display When PRESS BUTTON ON DEVICE TO REMOVE displays press the program button on the Z Wave device the device name and REMOVED is displayed to indicate the Z Wa...

Page 30: ...enter the new level 1 10 and Press COMMAND 4 The Favorite name and the next Z Wave device stored in the system displays Doors 1 Press any Select key at SETTING and LOCK UNLOCK for Doors and OPEN CLOSE...

Page 31: ...e REMOVE DEVICE FROM FAV NO YES displays When YES is selected the device is removed from the Favorite 17 12 Transfer Controller XFER This option allows the transfer of all existing Z Wave devices that...

Page 32: ...2 Press COMMAND until ZWAVE SETUP displays 3 Press any Select key The keypad displays ADD LIST REMOVE 4 Press COMMAND again to display FAV XFER OPT 5 Select OPT the keypad displays OPTIMIZE while the...

Page 33: ...communications Contact ID Recvd This displays DTMF digits dialed from the burglary control panel Exiting the Diagnostics program Press the COMMAND key until STOP displays Press any Select key The key...

Page 34: ...r zone 1 If zone 1 trips and zone 2 trips within the Cross Zone Time an ALARM report is sent to the receiver for zone 1 and zone 2 Note To operate correctly all cross zone zones need to be programmed...

Page 35: ...00 to exit 6 Define Output 17 actions Enter or displays Press and Field displays Enter 80 and program the following a Program Output 17 to turn on when armed Stay Output Funct Enter 01 press to conti...

Page 36: ...DATA USE SA4120XM 1 CABLE 1 2 3 4 5 6 7 8 OUT 17 12 AUX GND OUT 18 VISTA 20P ONLY GND OUT2 Z1 1K Ademco Vista 20P Remote Arming out to Keyswitch Arming Zone Armed Output of Vista to CellComSL Arming...

Page 37: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 HI HI HI LO LO LO LO HI HI LO LO HI HI LO LO HI TIP BROWN RING GRAY TIP GREEN RING RED BLACK RED SYNC COM DATA USE SA4120XM 1 CABLE 1 2...

Page 38: ...5803 8877 15165 Specifications Primary Power Nominal 12Vdc Current Draw Alarm 210 mA Standby 210 mA Dimension Housing 5 5 W x 3 75 L x 1 H Color White Ordering Information iComSLC Certifications Calif...

Reviews: