Digital Monitoring Products
iComSL
Series Universal Communicator Installation and Programming Guide
4
Applications
The iComSL Series Communicator can be used in a variety of applications:
3.1 CID
Dialer Connection
Directly connect the telco phone line (tip and ring) from the control panel to the iComSL to capture Contact
ID messages that are based on the SIA communication standard
DC-05-1999.09-DCS. These messages are
then formatted into a Serial 3 message and sent to a DMP Model SCS-1R or SCS-VR Receiver. Note: CID Dialer
Connection cannot be used when using Zone 4 Bell Connection.
Figure 8: iComSL Series Wiring Diagram for Tip and Ring Connection
Use 18-22 AWG for
Power Supply connection
Z3
+
Z4
+
Z4
-
GN
D
12 VDC Aux. Output
+
-
Ground
Control Panel
The panel or separate power
supply must be 12 Volt Regulated
and Power Limited.
Z1
+
Z2
+
RESET
S1
LOAD
S2
B
AT
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
J8
J26
J9
S1
S2
S3
1k ohm
1k ohm
1k ohm
1k ohm
MODEL
iComSLC
Figure 9: iComSL Series Wiring Diagram for Zones 1 - 4
Use 18-22 AWG for
Power Supply connection
CON
TROL PA
NEL TIP
CON
TROL PA
NEL RIN
G
12 VDC Aux. Output
+
-
Ground
Control Panel
The panel or separate power
supply must be 12 Volt Regulated
and Power Limited.
Telephone
Jack
Connector
BELL -
BELL +
RESET
S1
LOAD
S2
B
AT
PROG
S N
+12
G
Z1
Z2
Z4-
Z4+
G
Z3
R
T
O2
O1
R
B
J8
J26
J9
S1
S2
S3
MODEL
iComSLC
3.2
Zones 1 - 4 Input Connection
Connect each burglary control panel relay output to a iComSL Series Communicator zone. For programming
purposes, the zone numbers are 1 - 4. (See Figure 9 for wiring details). An example of how you might use this
application: You can use a normally closed output on the burglary control panel to indicate a burglary alarm. The
iComSL zone should be programmed with a zone name and zone type of Burg. When the output on the control
panel turns on and trips the iComSL zone, a message will be sent to an SCS-1R or SCS-VR receiver at Central
Station. You could use the zone name programming to describe which control panel zone indicated a burglary.
Note: Zone 4 can only be used as a standard input zone when not programmed as zone type Auxiliary 2 (A2). See
Zone 4 Bell Connection.
applIcatIons