SuperSigma2 AM PMS
–
V1.5.6 17-1-2020
Page 58 (97)
©2019 DMC GmbH Herten Germany
5.2
Menu 3
“
Controller Setup for Pump
”
A pump controller is always in speed control mode. Other changes to the Controller Setup compared to the traction
controller setup are:
Cal.
Ref.
Parameter
Calibrator
text
Options (defaults are in bold)
Range
1
Accel. Characteristic
Lin/Curv
0 = Accelerator linear
1 = Accelerator curved
0
–
1
2
Speed 6 input normally
closed or normally open
Sp6NO/NC
0 = Normally open
1 = Normally closed
0
–
1
3
Inhibit input normally
closed or normally open
HibNO/NC
0 = Normally open
1 = Normally close
0
–
1
4
Enable power up checks
Nchk/Chk
0 = D
on’t check
1 = Check
0
–
1
5
Enable pot with switch
NoSw/Sw
0 = No switch
1 = With switch
0
–
1
6
Display Status field
Of/D/V/K
0 = None
1 = Accelerator [%]
2 = Motor Velocity [RPM]
3 = no effect
4 = no effect
5 = Motor current [A]
6 = Battery current [A]
0
–
6
7
Digital O/P 4 config
DO4Typ
0 = Remote LED
1 = Drive OK
0
–
1
8*
Active low or high digital
inputs
Actv L/H
0 = Active low digital inputs
1 = Active high digital inputs
0
–
1
9
Accelerator supply wire
off detection
SplyWrOf
0 = No supply wire off detection
1 = 0V wire off detection enabled
2 = 5V wire off detection enabled
3 = Both 0V and 5V wire off detection
0
–
3
10
Line Contactor pull-in
level
LCPlInLv
Adjustable from 50% to 100% Ubatt.to limit inrush
current.
Default is 90%
50-100%
11
Line Contactor pull-in
time out
LCPlInTO
Line Contactor pull in time out.
Default is 10sec
.
0-12 sec
12
Line Contactor Coil pull-in
Voltage
LCPlInVl
Adjustable from 5% to 100% Ubatt
Default is
100%
7-100%
13
Line Contactor Coil
Holding voltage
LCHoldVl
Adjustable from 5% to 100% Ubatt
Default is
100%
7-100%
14
Digital output 2 pull-in
voltage
DO2PlInV
Adjustable from 7% to 100% Ubatt
Default is
100%
7-100%
15
Digital output 2 hold
voltage
DO2HoldV
Adjustable from 7% to 100% Ubatt
Default is
100%
7-100%
16
Digital output 3 pull-in
voltage
DO3PlInV
Adjustable from 7% to 100% Ubatt
Default is
100%
7-100%
17
Digital output 3 hold
voltage
DO3HoldV
Adjustable from 7% to 100% Ubatt
Default is
100%
7-100%
18
Drive output 2
Configuration
Drv2Cfg
0 = no function
1 = motor temperature cooling enabled
2 = controller temperature cooling enabled
3 = both motor and controller temperature
cooling enabled
0
–
3
19
Drive output 3
Configuration
Drv3Cfg
0 = no function
1 = motor temperature cooling enabled
2 = controller temperature cooling enabled
3 = both motor and controller temperature
cooling enabled
0
–
3
20
Drive Output Motor Temp
TH
MotTmpTh
Adjustable from 10 to 127 °C.
Default is 70 °C
10
–
127
°C