Closing the device
The front is attached to the base unit using hexagonal screws (M5 x 20 with an inside
diameter of 3 mm). In all devices, these screws must be retightened with a torque
wrench.
Retighten all the hexagonal screws in a
cross-wise
pattern to the following torque:
DLoG X 7:
3 Nm
DLoG X 10:
3 Nm
DLoG X 12:
4 Nm
Tighten both screws in the temporary cap and antenna cap to a torque of
1 Nm
.
Please be aware that any test marks and the guarantee may lose their validity if the
device has been improperly operated or opened/closed. For devices compliant with
protection class IP65, for example, DLoG GmbH no longer guarantees the safety
rating if the device has been improperly opened or closed by persons insufficiently
qualified.