background image

Web Power Switch 

Pro

digital-loggers.com

18

Limited Five Year Warranty

The terms of this warranty may be legally binding. If you disagree with the terms 

below, return the product immediately in original unopened condition for a full 

refund. The purchaser assumes the entire risk as to the results and performance 

of the unit. DLI makes reasonable effors to snure that this power controller is free 

of major defects. No agency, country, or local certifications are included with this 

unit. It is the responsibility of the user to obtain such certifications if necessary 

for the customer’s application. Buyer acknowledges and agrees that he is solely 

responsible for proper use, certification and safety testing of components supplied 

by DLI. DLI’s entire liability and exclusive remedy as to defective hardware shall 

be, at DLI’s option, either (a) return of the purchase price or (b) replacement or 

repair of the hardware that does not meet DLI’s quality control standards and 

has been returned through proper RMA procedures. DLI’s liability for repair 

or replacement is to DLI’s customer ONLY.  NO SUPPORT IS PROVIDED 

FOR MODIFIED FIRMWARE.  MODIFICATION OF FIRMWARE VOIDS ALL 

WARRANTY.  Warranty service requires an original invoice from DLI and an RMA 

number provided by technical support. RMA material must be shipped prepaid to 

DLI. RMA numbers are valid for 15 days from date of issue. This warranty does not 

cover products which are modified (including firmware modifications), subjected to 

rough handling, or used in applications for which they were not originally intended. 

Batteries are not covered under warranty. Physical damage caused by customer 

or in transit to DLI is not covered under warranty.  Please insure shipments. No 

oral advice or verbal warranties made by DLI’s employees, dealers, or distributors 

shall in any way increase the scope of this warranty. DLI makes no warranty as to 

merchantability or fitness for any particular purpose. DLI assumes no liability for 

incidental or consequential damages arising from the use or inability to use this 

product. This warranty gives you specific legal rights. You may also have other 

rights that vary from state to state. Since some states do not allow the exclusion of 

liability for consequential damages, some of the above limitations may not apply. 

Auto-Ping

TM

 is a registered trademark of Computer Performance, Inc. Since this 

is a FLASH based product, firmware should not be updated over the Internet or a 

busy LAN. Packet loss could result in FLASH corruption, requiring mail-in service. 

This product is designed for indoor use only. It should not be used for outdoor, 

mobile, airborne, or FDA Class III applications.

DIGITAL LOGGERS, INC. 

2695 Walsh Avenue

Santa Clara, CA 95051

Digital-Loggers.com

[email protected]

© 2003-2018 DLI This product is protected by pending US patents and foreign patents 

Released 12/16/2018

Summary of Contents for Pro

Page 1: ...USER S GUIDE Web Power Switch Pro ...

Page 2: ...ed Outlets are spaced for plugs and adapters Un switched outlets are provided for always on devices Programmable LCD Display Keypad A 2x16 LCD displays status for each outlet Custom messages can be displayed via user scripts A keypad adds local control Outlet states may be locked and the admin can disable the keypad Multi User Password Security Multi user authentication limits access to the Pro Th...

Page 3: ...d a connection for external enviromental ie temperature sensors Field Upgradeable Firmware Firmware is field upgradeable via Ethernet Package Contents Web Power Switch Pro with NEMA 5 15 plugs RP SMA WiFi Antenna C 19 to 5 15 power cord for 120V use Options Custom length cords plugs digital loggers com cords html L shaped bracket for vertical rack mounting External temperature sensor External powe...

Page 4: ...ng the default address 192 168 0 100 to confirm that a network connection is established If you don t receive a response proceed to the IP Setup section below Log in to the Pro using the default user name admin and the password 1234 Note admin must be entered in lower case Click the Settings link to reach the configuration page Select the safest power loss configuration for your installation all O...

Page 5: ...ght click on LocalArea Network Connection and select Properties Proceed to step 2 Windows Vista Open Start right click on Network then on Properties Double click Network and Sharing Center click Manage Newtork Connections A Network Connections window appears Right click on the network connection to the switch ie Local Area Network Proceed to step 2 Windows 7 Open the Start orb click on Control Pan...

Page 6: ...s then Network Select Built In Ethernet and then Configure Under the TCP IP tab select Manually and enter an IP address such as 192 168 0 0 as shown Make changes shown Point a browser to 192 168 0 100 Log in Find Mac setup details at digital loggers com mac_ip_setup Network Configuration HTTPS is disabled by default WiFi is enabled with a random key Start by establishing a hard wired network conne...

Page 7: ...Some browsers deny connections to ports under 1024 by default Setup and Control via Keypad In addition to setup via LAN you may use the keypad and display to get started and to manually control the basic functions of the switch This section describes basic keypad usage Press any key to activate the keypad If you don t receive a response they keypad is locked out see below Outlet port or relay stat...

Page 8: ...ly in the OFF state it can be locked by holding 0 and unlocked by holding 1 Although the web interface is more commonly used the keypad can be helpful for initial setup and for minor changes To enter network setup press UP and DOWN keys simultaneously Network setup consists of several pages Use the CYCLE key to loop through them UP and DOWN are used to select a field within the page Pressing 1 mea...

Page 9: ...b configuration protection Network settings are locked on the web setup page when protection is enabled Press 1 to activate protection 0 to deactivate If you are installing the switch in a remote location bear in mind you will need physical access to the switch to unlock it Password for admin user Press 0 to leave the password unchanged Press 1 to assign a new random case sensitive password Save D...

Page 10: ...Fi Clears protection bits resets network settings and admin login disables autoping and scripts and enables open WiFi access Other settings are preserved Complete Wipe Resets all settings to factory defaults and remove any user files All settings will be lost Complete Wipe enable WiFi Resets all settings to factory defaults and removes any user files then enables open WiFi access All settings are ...

Page 11: ...power loss recovery mode You can also add user accounts and change login credentials on this page Scripting The Lua language lets you easily customize the Pro Scripts may be started manually automatically on power up by external http commands or by AutoPing events Find a list of commands and examples at digital loggers com scripts html AutoPing The AutoPing page lets you set parameters to automati...

Page 12: ...ing Use the keypad for local control Select an outlet using the arrow keys then press on off or cycle Press ON or OFF for 5 seconds to lock or unlock an outlet Locking prevents web access To change the display mode press the up and down arrows simultaneously The keypad may be disabled on the Setup page You may want to Cycle a device which is connected to the Pro This feature is useful for rebootin...

Page 13: ...u may also enter a screen refresh delay in this section If Enable screen refresh is checked and a delay value is entered your browser should periodically update the status screen Wrong Password Lockout After three failed login attempts the Pro can disable access for a selected period of time Power Loss Recovery Modes The power loss recovery mode setting has a very important setting that determines...

Page 14: ...t human intervention AutoPing will monitor a device If it stops responding AutoPing can cycle power to reboot it For example you might use AutoPing to monitor an external multi cast IP to automatically reboot a DSL router or WiFi AP To use AutoPing first add an IP address Next link that IP address to one or more outlets Timing settings must be considered Add IP Address to AutoPing Use this option ...

Page 15: ...which may take several minutes to complete To allow for startup delays enter a time delay in the Device Reboot Delay period For example a reasonable value for a typical server might be 10 minutes 600 seconds Entering 600 would cause the power controller to start checking the server for normal IP operation 10 minutes after reboot AutoPing TM Example In this example we use AutoPing to automatically ...

Page 16: ...DLI Learn more digital loggers com mobile html Real Time Clock An internal Real Time Clock RTC is provided This clock can be set manually using the Date Time link The time zone can be selected based on GMT Internal batteries have an estimated 15 year lifetime Lua Scripting The controller can be customized using the Lua language A full description is beyond the scope of this manual so please take a...

Page 17: ...provided for reference Purchasing a TLA and signing an NDA from Atheros are highly recommended before attempting any custom development DLI can t provide warranty or offer tech support for modified units Technical Support FAQs Please register Painless on line registration gets you free tech support access to firmware updates and information when updates and new features become available Take advan...

Page 18: ...Web Power Switch Pro digital loggers com Latest Manual FAQs AutoPing Rack Mount Model Scripting DLI Homepage ...

Page 19: ...CSA 15A 5 15 120VAC only Input Frequency Power supply DC 400Hz Operating Temperature 30º to 170ºF 34º to 77ºC Options Factory Input cord length and 120V plugs rack bracket Power Supply Rating 90 240V AC DC Autosensing Password Transmission Encrypted base 64 or HTTPS Power Dissipation 3 9W Typ Max all on 3 W idle Power Fail Hold Over 200ms minimum all relays on Power Up Modes Last used settings all...

Page 20: ...rs are valid for 15 days from date of issue This warranty does not cover products which are modified including firmware modifications subjected to rough handling or used in applications for which they were not originally intended Batteries are not covered under warranty Physical damage caused by customer or in transit to DLI is not covered under warranty Please insure shipments No oral advice or v...

Page 21: ...Web Power Switch Pro 19 Compatible Products Call 408 330 5599 2x50A 8x15A DC Smart Switch 12 24 or 48 Smart PoE Injector 90 240VAC Smart PDU DIN Relay ...

Page 22: ...2695 Walsh Ave Santa Clara CA 95051 408 330 5599 digital loggers com ...