1812-162-V-5-16
37
2.6.5 Delete an Access Code (Simple and Time Zone Restricted)
This programming sequence deletes individual “simple” and “time zone restricted” access codes that have been
programmed into the system.
1.
Press
*
7 1 and enter the MASTER CODE.
[
*
7 1 _ _ _ _ (beep)]
2.
Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
*
.
[ _
*
(beep)]
3.
Enter the five-digit device access code to be deleted, then press
*
.
[ _ _ _ _ _
*
(beep)]
See 2.6.1 and/or 2.6.4 for the five-digit access code.
4.
Repeat steps 2 and 3 to delete additional existing “simple” and “time zone restricted” access codes.
5.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
2.6.4 “Time Zone Restricted” Access Code Programming
This programming sequence programs access codes into the system memory
with time zone restrictions applied
. It also
allows programming of the
access codes to momentarily activate a relay or to hold open (latch) a relay.
Note: Up to 50 access codes can be programmed into the system. This 50 includes “simple” access codes programmed in
2.6.1
AND
“time zone restricted” access codes programmed in 2.6.4. For example, if 10 “simple” access codes are
programmed in 2.6.1, then only 40 “time zone restricted” access codes can be programmed in 2.6.4.
1.
Press
*
7 0 and enter the MASTER CODE.
[
*
7 0 _ _ _ _ (beep)]
2.
Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
*
.
[ _
*
(beep)]
3.
Choose and enter a five-digit access code, then press
*
.
[ _ _ _ _ _
*
(beep)]
4.
Enter a minimum of 1, and a maximum of 4 time zones (valid time zones are 0 through 6) that you
want to apply to this access code, then press
*
.
[ _ _ _ _
*
(beep)]
Time zone 0 - Always deny access.
Time zone 1 - Allows 24/7 access for relay 1 and any additional relays.
Time zone 2 - Allows 24/7 access for relay 2 and any additional relays.
Time zones 3, 4, 5 and 6 - Are time zones that have been programmed in 2.7.6.
5.
Enter 0
*
for momentary relay activation or enter 1
*
to hold open (latch) the relay.
[ _
*
(beep)]
6.
Repeat steps 2 through 5 to program additional access codes (Time zone restricted).
7.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
2.6.6 Delete All Access Codes for the Same Type of Device (Simple and TZR)
This programming sequence deletes
ALL
existing “simple” and “time zone restricted (TZR)” access codes
for the same
type of device.
To delete
ALL
existing “simple” and “time zone restricted” access codes, this programming sequence will
need to be preformed for each type of device that is connected to the system.
WARNING: Once started, all “simple” and “time zone restricted”
access codes for the same type of device will be erased.
1.
Press
*
7 2 and enter the MASTER CODE.
[
*
7 2 _ _ _ _ (beep)]
2.
Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
*
.
[ _
*
(beep)]
3.
Press 9 9 9 9, then press
*
.
[ 9 9 9 9 (beep)]
4.
The programming sequence will end itself automatically.
[beeeeeep]
Summary of Contents for 1812 Plus