2.6 Access Codes to Operate Access Control Devices
2.6.1 “Simple” Access Code Programming (Relays 1&2: 24/7 Operation)
This programming sequence programs “simple” access codes used on the 1812 keypad into the system memory. “Simple”
access codes CANNOT be time zone restricted; they can
ONLY
be assigned to operate the internal
Relay 1
or
Relay 2
on a
24/7 basis using the relay strike time programmed in section 2.4.7. If you require access codes to be “time zone
restricted”, use the programming sequence in 2.6.4.
Note: Up to 50 access codes can be programmed into the system. This 50 includes “simple” access codes programmed in
2.6.1
AND
“time zone restricted” access codes programmed in 2.6.4. For example, if 10 “simple” access codes are
programmed in 2.6.1, then only 40 “time zone restricted” access codes can be programmed in 2.6.4.
1.
Press
*
0 2 and enter the MASTER CODE.
[
*
0 2 _ _ _ _ (beep)]
2.
Press 1 for relay 1
OR
Press 2 for relay 2, then press
*
.
[ _
*
(beep)]
3.
Choose and enter a five-digit “simple” access code, then press
*
.
[ _ _ _ _ _
*
(beep)]
4.
Repeat steps 2 and 3 to enter additional “simple” access codes.
5.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]