1812-162-V-5-16
29
STOP!
If you are
OR
are going to use a computer with the 1812 Access Plus,
NO other programming at the System
Keypad is required.
All programming parameters beyond this point can be set in the Management software.
This software will show all the specific programming parameters that will exist in the memory of the 1812 after it has been
programmed. It can be easily recalled for future modification or re-programming.
The system keypad
DOES NOT
have the capability to show any of the programming that will exist
in the memory of the 1812 after being programmed. The only way to keep track of the specific
parameters that have been programmed into the 1812 for future reference when
NOT
using the
management software, is to physically write down all the information in a log (In back of manual).
2.3.3 Sub-Net Mask
(reboot required)
Factory setting is: 255.255.255.000
All sub-net mask should be set to 255.255.255.000. This rarely needs to be changed, consult with your network expert
first. Valid values for any of the three digit numbers is 000 to 255.
1.
Press
*
5 2 and enter the MASTER CODE.
[
*
5 2 _ _ _ _ (beep)]
2.
Enter the sub-net mask number. Use the
*
key to enter the “dot”.
[ _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
77
88
99
44
55
66
00
System Keypad
2.3.4 Set the Gateway (Router) IP Address
(reboot required)
Factory setting is: 192.168.001.001
If the 1812 is connected directly to the computer with a crossover cable, then this address must be set to 000.000.000.000.
If the 1812 is connected to the computer through a router, then set this value to the router’s IP address. Valid value for any
of the three digit numbers is 000 to 255. (See pages 23 and 24 for network configurations and addresses)
1.
Press
*
5 3 and enter the MASTER CODE.
[
*
5 3 _ _ _ _ (beep)]
2.
Enter the gateway (router) IP address. Use the
*
key to enter the “dot”.
[ _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep) _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
77
88
99
44
55
66
00
System Keypad
2.3.5 Set the Port Number
(reboot required)
Factory setting is: 01030
This must be the same port number that was programmed in the software. Valid values are 01024 to 65535.
All 5 digits must be entered in the field, for example: 1030 must be entered as 01030
1.
Press
*
5 6 and enter the MASTER CODE.
[
*
5 6 _ _ _ _ (beep)]
2.
Enter the port number, then press
*
.
[ _ _ _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
77
88
99
44
55
66
00
System Keypad
SOFTW
ARE
INST
ALLED
SOFTW
ARE
INST
ALLED
SOFTW
AR
E
IN
STAL
LED
77
88
99
44
55
66
00
PC’s only, NOT for use with MACs
Summary of Contents for 1812 Plus