2.4.6 Talk Time
Factory setting is 060 (60 Seconds).
This programming sequence sets the maximum time allowed for conversation when the 1812 places a call to the resident’s
house,
or
if call forwarding is active,
or
if any of the dial out numbers are used. Talk time can be set from 10 seconds up to
255 seconds (4 minutes, 15 seconds) and is entered as a three-digit number. For example, to set a talk time of 30 seconds,
enter 030 in step 2.
1.
Press
*
0 8 and enter the MASTER CODE.
[
*
0 8 _ _ _ _ (beep)]
2.
Enter the three-digit talk time code (010-255), then press
*
.
[ _ _ _
*
(beep)]
3.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
2.4.7 Relay Strike Time
Factory setting for Relays 1 and 2 is 01 (1 Second). Relays 3 through 8 are not set.
These steps will program the system relay strike times.
Strike times can be programmed from 1/4 second - enter 0 0 * in step 3, up to 99 seconds - enter 9 9 * in step 3.
System relays 1 and 2 are the two relays on the 1812 main circuit board. System relays 3 through 8 are the relays
associated with additional RS-485 devices (card readers, keypads, RF receivers, etc.) connected to the system.
1.
Press
*
0 3 and enter the MASTER CODE.
[
*
0 3 _ _ _ _ (beep)]
2.
Enter a relay number (1 – 8), then press
*
.
[ _
*
(beep)]
3.
Enter the two-digit strike time (00-99), then press
*
.
[ _ _
*
(beep)]
4.
Repeat steps 2 and 3 to set other relay strike times if necessary.
5.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
1.
Press
*
0 5 and enter the MASTER CODE.
[
*
0 5 _ _ _ _ (beep)]
2.
Enter a relay number (1 – 8), then press
*
.
[ _
*
(beep)]
3.
Choose and enter a four-digit tone open number code (see chart below), then press
*
.
[ _ _ _ _
*
(beep)]
If a tone open function is not desired, enter # in place of a number.
4.
Repeat steps 2 and 3 to set other relay tone open number(s) if desired.
5.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
2.4.8 Tone Open Numbers
Factory setting is 9876 for Relay 1; 5432 for Relay 2. Relays 3 – 8 are not set.
These steps will program the tone open number(s) for each relay in the system (each relay is programmed independently).
You will need to enter a four-digit number (see chart below) to set each relay in step 3. If a function is not desired, enter #
in place of a number. Use a different number for each of the four-digits in step 3 when multiple functions are desired.
Example 1: If you want the relay to have a momentary activation function only, and you want the relay to activate when the
number 9 is pressed, enter 9 # # #
*
in step 3.
Example 2: If you only want the relay to hold open when the number 8 is pressed and the relay deactivated when the
number 7 is pressed, enter # 8 7 #
*
in step 3.
1st Digit (Step 3)
2nd Digit (Step 3)
3rd Digit (Step 3)
4th Digit (Step 3)
Momentary activation. The relay will activate for its programmed relay strike time.
Hold open. The relay will activate and remain activated until commanded to deactivate.
Deactivate relay.
Hold open 1 hour. The relay will activate for 1 hour and then deactivate itself.
4 Digit Tone Open Number Code
Function