Installation/Owner’s Manual

Model 1812 Access Plus

Model 1812 Access Plus

Model 1812 Access Plus

Use this manual for circuit board 1970-010 Revision U or higher.

Control a main door, gate and six additional RS-485 entry points.

PC Programmable Residential Telephone Intercom/Access Control System

1812-162-V-5-16

Summary of Contents for 1812 Plus

Page 1: ...6 1 2 3 0 7 8 9 4 5 6 1 2 3 0 7 8 9 4 5 6 1 2 3 0 7 8 9 4 5 6 1 2 3 0 Surface Mount Curved Wall Mount Flush Mount Surface Mount Installation Owner s Manual Model 1812 Access Plus Model 1812 Access Pl...

Page 2: ......

Page 3: ...Holiday schedule 500 event transaction buffer Unique distinctive ring Unit connects directly to the homeowners existing telephone line No additional monthly expense for a second telephone line Built i...

Page 4: ...5 5 6 6 1 1 2 2 3 3 0 0 7 7 8 8 9 9 4 4 5 5 6 6 1 2 3 0 0 1 1 1 1 2 2 2 2 3 3 3 3 3 3 7 7 8 8 9 9 4 4 5 5 6 6 1 2 3 0 0 1 1 1 1 2 2 2 2 3 3 3 3 3 3 10 5 25 11 6 25 6 125 6 75 2 5 2 5 1 125 Dia 2 875 1...

Page 5: ...1 1 2 2 2 2 3 3 3 3 3 3 7 5 6 25 7 25 9 25 7 325 5 3 5 3 5 10 25 10 10 75 3 5 12 4 5 4 25 2 625 2 5 2 5 875 Dia 5 2 5 1 125 Dia 1 25 Dia Rough In Box Rough In Box Rough In Box Flush Box Flush Box Bolt...

Page 6: ...isy Chain Wiring RS 485 Configurations Samples of Multiple 1812 Configuration Connections Telephone Mode or Intercom Mode 1 12 2 Network Connections 1 12 3 Phone Modem Connections SECTION 2 PROGRAMMIN...

Page 7: ...e Factory Settings 2 8 2 Erase Transaction Log SECTION 3 ADJUSTMENTS Speaker Volume Microphone Gain Interface Board LED Status System Keypad and Push to Call Button SECTION 4 USER INSTRUCTIONS 4 1 Res...

Page 8: ...he customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian...

Page 9: ...rcumstances should the unit be mounted directly to a moving door or gate ADA mounting requirements for door control The requirements below apply only when the telephone entry system is being used to c...

Page 10: ...1 1 Mount the 1812 Access Plus The control board removal is the same for all models 1 Unlock and open the 1812 door 2 Disconnect the keypad plug and door accessories plug from the control board 3 Remo...

Page 11: ...ing post Note A gooseneck mounting post anchored in concrete does not make a good ground Mount on a Mounting Post IMPORTANT Choose how your 1812 will function Telephone Mode or Intercom Mode on pages...

Page 12: ...lt flush box into the rough in box with 4 supplied bolts Flush Mount in a Pilaster Wall or Kiosk Re install the Control Board Rough In Box SPEAKER VOL MIC VOL KEYPAD OV MASTER CODE 1970 010 18 11 1 2...

Page 13: ...e 1812 s by pass board provides a method to by pass the 1812 and route the incoming telephone line directly to the homeowner s phone The By Pass board IS NOT optional when using an incoming telephone...

Page 14: ...re can cause noise and hum on the phone line Be sure that phone wire pairs are twisted Wire Size and Distance Phone lines can be run up to 3600 feet provided that the proper wire size is used 1 3 Tele...

Page 15: ...and the use of surge suppressors can significantly reduce the chance of component failure because of static charges or surges To be effective ground connections should be made with a minimum 12 AWG w...

Page 16: ...ly recommended For best protection surge suppressor ground wire MUST be 3 ft or less in length Use minimum 12 AWG wire Refer to instruction sheet included with surge board for complete information Sep...

Page 17: ...ical Existing Internet Source Check Polarity of Telephone Line Check for polarity on the incoming telephone line to each board and maintain polarity throughout the telephone line One potential problem...

Page 18: ...C 14 N O 13 Com 12 N C 11 N O 10 9 8 7 6 5 RING 4 TIP 3 GND 2 TIP 1 RING 16 5 VAC Relay 1 Relay 2 Power Last 1812 See previous 2 pages for wiring and information See previous 2 pages for wiring and i...

Page 19: ...3 Com 12 N C 11 N O 10 9 8 7 6 5 RING 4 TIP 3 GND 2 TIP 1 RING 16 5 VAC Phone In TIP White blue mark RING Blue white mark Telephone Line For complete information see page 12 Phone Out Intercom Mode Co...

Page 20: ...Phone In 1st 1812 Phone Mode 2nd 1812 Phone Mode 3rd 1812 Phone Mode 4th 1812 Phone Mode 5th 1812 INTERCOM MODE Phone Out Phone Out Phone In Phone In Phone Out 7 7 8 8 9 9 4 4 5 5 6 6 0 0 7 7 8 8 9 9...

Page 21: ...nd or RF receivers using RS 485 communication protocol The 1812 Access Plus can be programmed via a PC using a network or modem connection An RJ 45 jack Cat5 is provided on the interface board for net...

Page 22: ...terminal 6 on the RS 485 board If wiring will be outdoors or under ground use Cat5e Gel Filled flooded UV Resistant Direct Burial Cable Any RS 485 Keypad Cardreader and MicroPlus RF Receiver sequence...

Page 23: ...s RF receiver must have a unique address assigned to it starting with 003 The address selector switches are located on the RS 485 circuit board see instruction sheets that come with each RS 485 device...

Page 24: ...Phone In Phone In Phone In Phone Out By Pass Board 7 7 8 8 9 9 4 4 5 5 6 6 0 0 1st 1812 Phone Mode Unique Master Code 2nd 1812 Phone Mode Unique Master Code 3rd 1812 Phone Mode Unique Master Code 4th...

Page 25: ...istance on Cat5 wire run is limited to 325 feet 100 meters Maximum distance on Cat5 wire run Crossover cable is limited to 325 feet 100 meters Note Router address is set to 192 168 001 001 See 2 3 4 S...

Page 26: ...th Internet Access Wireless is optional Internet Phone Company or Cable Company Input RJ 45 RJ 45 RJ 45 RJ 45 Cable Cat5 Internet 1 2 3 4 Cat5 Cat5 for LAN Connection Cat5 for WAN Connection Wired or...

Page 27: ...e Phone Modem Connection 1812 and PC connected on DIFFERENTphone lines SOFTWARE INSTALLED RJ 11 External phone modem connection to the PC shown Internal phone modem connection to the PC shown To Phone...

Page 28: ...rence There is no way of retrieving the master code after it has been programmed in If you forget it you will have to program in a new one but all other previously programmed information will remain i...

Page 29: ...system transaction log Computer PC s only NOT for use with MACs This is the preferred method of programming the 1812 Access Plus as it will simplify all of the programming steps and allow you to enjoy...

Page 30: ...all other network setup programming sequences have been completed 2 3 2 through 2 3 5 or whenever an individual network programming step is performed Once the 1812 is connected the green LED on the RJ...

Page 31: ...e dot _ _ _ beep _ _ _ beep _ _ _ beep _ _ _ beep 3 Press 0 TOGETHER to end 0 beeeeeep 7 7 8 8 9 9 4 4 5 5 6 6 0 0 System Keypad 2 3 4 Set the Gateway Router IP Address reboot required Factory setting...

Page 32: ...anual The system will prompt you with short beep tones when programming steps have been followed correctly 3 When complete hang up You cannot use 0 pressed together to end programming steps from a tou...

Page 33: ...ramming Relays 1 2 24 7 Operation Time Zone Restricted Access Code Programming Delete an Access Code Simple or Time Zone Restricted Delete All Access Codes for the Same Type of Device Simple or TZR Em...

Page 34: ...the phone line 1 Press 6 1 and enter the MASTER CODE 6 1 _ _ _ _ beep 2 Press 1 for a single system OR press 0 for multiple systems _ beep 3 Press 0 TOGETHER to end 0 beeeeeep 2 4 3 System Attention...

Page 35: ...ETHER to end 0 beeeeeep 1 Press 0 5 and enter the MASTER CODE 0 5 _ _ _ _ beep 2 Enter a relay number 1 8 then press _ beep 3 Choose and enter a four digit tone open number code see chart below then p...

Page 36: ...er the tone open number is used Only one activation number will function per phone call Example If you call and want to Hold Open the relay you will have to call back to Deactivate it later 3 Hang up...

Page 37: ...system memory WARNING once started all phone numbers will be erased 1 Press 4 3 and enter the MASTER CODE 4 3 _ _ _ _ beep 2 Press 9 9 9 9 then press 9 9 9 9 beep 3 The programming sequence will end i...

Page 38: ...me zone restricted use the programming sequence in 2 6 4 Note Up to 50 access codes can be programmed into the system This 50 includes simple access codes programmed in 2 6 1 AND time zone restricted...

Page 39: ...vice type 0 card 1 transmitter 2 keypad 3 other then press _ beep 3 Choose and enter a five digit access code then press _ _ _ _ _ beep 4 Enter a minimum of 1 and a maximum of 4 time zones valid time...

Page 40: ...forward see 2 7 3 below 1 Press 1 0 and enter the MASTER CODE 1 0 _ _ _ _ beep 2 Enter the phone number where calls from the 1812 are to be forwarded to up to 20 digits no dashes then press _ _ _ _ _...

Page 41: ...he other auto relay time zones up to 4 if desired 11 Press 0 TOGETHER to end 0 beeeeeep 2 7 6 Access Code Time Zone Programming Up to 4 Factory setting in step 3 is 0 Time Zones are OFF This programmi...

Page 42: ...to factory settings 1 Press 9 0 and enter the MASTER CODE 9 0 _ _ _ _ beep 2 Press 9 9 9 9 then press 9 9 9 9 beep 3 The programming sequence will end itself automatically beeeeeep 2 8 2 Erase Transa...

Page 43: ...andset is set to a comfortable level RS 485 RX Green LED indicates that the system is on line and scanning the RS 485 devices BAD DNS Yellow LED indicates an email server problem rejecting the mail se...

Page 44: ...he outside call on HOLD and talk to the guest press 2 To grant the guest access press the programmed tone open number The 1812 will respond with a confirming tone open the door or gate then press to r...

Page 45: ...een disabled see 2 4 9 Refer to the tone open numbers that where programmed in section 2 4 8 to determine each of the activation numbers Only one activation number will function per phone call Example...

Page 46: ...l cause problems with the entry system 3 Check the polarity of the phone lines See section 5 2 on the next page 4 Be sure that the entry system case is properly grounded 5 Be sure that the telephone w...

Page 47: ...Jack Phone Jack Cat5e Cat5e Without Surge Board Cat5e Cat5e To Surge Board Cat5e Homeowner s Phones Check that all boards are properly grounded with 12 AWG gauge wire minimum By Pass Board PHONE IN 3...

Page 48: ...e If the noise is gone problem is with or in the 1812 unit or with the power supply or power wiring Reconnect the PHONE IN wires to terminals 1 and 2 and the PHONE OUT wires to terminals 4 and 5 then...

Page 49: ...Disconnect the PHONE OUT wires and connect a test telephone to the PHONE OUT terminals 4 5 If the 1812 cannot communicate with the test phone PHONE IN and PHONE OUT wires may be connected backwards Ch...

Page 50: ...suppressor P N 1878 010 Mounting Posts Gooseneck mounting post with concrete base plate P N 1200 045 Gooseneck mounting post direct burial P N 1200 046 Telephone Test Set Includes clips cord and carry...

Page 51: ...Beginning Time Ending Time Days of the Week Do Not Disturb Time Zone Beginning Time Ending Time Days of the Week Call Forward Time Zone Momentary Activation Hold Open Deactivate Relay Hold Open 1 Hr T...

Page 52: ...1812 162 V 5 16 50 Directory Codes 24 50 Dial Out Phone Numbers Name Phone Number Directory Code 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50...

Page 53: ...Phone Numbers Name Phone Number Optional 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Time Zone Number Relay Momentary or Hold Latch Access Code and Type Simple or Time Zone Rest...

Page 54: ...ne Numbers Name Phone Number Optional 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Time Zone Number Relay Momentary or Hold Latch Access Code and Type Simple or Time Zone...

Page 55: ...Log Sheet Access Only Name 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Time Zone Number Relay Momentary or Hold Latch Access Code and Type Simple or Time Zone Restricted Time Zon...

Page 56: ...Sheet Access Only Name 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Time Zone Number Relay Momentary or Hold Latch Access Code and Type Simple or Time Zone Restricted Tim...

Page 57: ...9 10 Time Zone Number Relay Momentary or Hold Latch Beginning Date Device Type Ending Date 1 10 Temporary Access Codes Log Sheet extra log sheet Temporary Access Code Name 1 2 3 4 5 6 7 8 9 10 Time Z...

Page 58: ...Model 1812 Access Plus Use this manual for circuit board 1970 010 Revision U or higher PC Programmable Residential Telephone Intercom Access Control System www doorking com DoorKing Inc 120 S Glasgow...