background image

                                                                                                                                                       

H-SW3000 USER MANUAL V1

 

< 6 > 

Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product has an appropriate 
electrical ground to avoid the risk of electrocution or fire. 

Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves 
only as a 0 to 100% switch. 

4.2

 

AC Plug  

The H-SW3000 comes with a power input cord terminated with a Lockable power connector on one end. The other end is  

 

CN plug (CN market, etc.) 

 

EU plug (EU market, etc.) 

 

US plug (US market, etc.) 

If the power input cord that came with your product has no plug, or if you need the change the plug, use the table below to wire the new 
plug: 

Connection 

Wire (U.S.) 

Wire (Europe) 

AC Live 

Black 

Brown 

AC Neutral 

White 

Blue 

AC Ground 

Green/Yellow 

Green/Yellow 

 

4.3

 

Resetting the Breaker 

This product is equipped with a resettable breaker. If the breaker trips, all sections of this product will lose power. 

 

Remove the power cord from mains power. 

 

Allow unit to cool for 15 minutes. 

 

After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger. 

 

Plug the product’s power cord into the power outlet and continue using as recommended.

 

4.4

 

DMX Linking 

You can link the H-SW3000 to a DMX controller using a 3- or 5-pin DMX connection. If using other DMX-compatible products with this 
product, you can control each individually with a single DMX controller. Instructions for connecting and configuring this product for DMX 
operation are in the User Manual. 

4.5

 

Mounting 

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. 

4.5.1

 

Orientation 

For safety reasons, we do not recommend mounting the product in any capacity. Operate the product while it is on the ground only, and 
make sure there is adequate room for ventilation, configuration, and maintenance. 

4.5.2

 

Rigging 

DJPOWER recommends using the following general guidelines when mounting this product. 

 

Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming 
purposes. 

 

Make sure that the structure or surface onto which you are mounting the product can support the product’s weight (see the Tec

hnical 

Specifications). 

 

When mounting the product on the floor, make sure that the product and cables are away from people and vehicles. 

Summary of Contents for H-SW3000

Page 1: ......

Page 2: ......

Page 3: ...ETTING THE BREAKER 6 4 4 DMX LINKING 6 4 5 MOUNTING 6 4 5 1 Orientation 6 4 5 2 Rigging 6 5 OPERATION 7 5 1 PREPARING FOR OPERATION 7 5 2 ON DEVICE CONTROL PANEL 7 5 3 ON DEVICE CONTROL MODE OPERATION 7 5 3 1 Programming 7 5 3 2 Menu Map 7 5 4 DMX MODE OPERATION 9 5 4 1 Starting Address 9 5 4 2 DMX Mode Menu Map 9 5 4 3 DMX Channel Assignments and Values 9 5 5 AUTO RUN LAST SETTINGS 10 5 6 FLUID S...

Page 4: ......

Page 5: ...tion Useful information 1 4 Disclaimer The information and specifications contained in this User Manual are subject to change without notice DJPOWER assumes no responsibility or liability for any errors or omissions and reserves the right to revise or to create this manual at any time Copyright 2018 DJPOWER All rights reserved 1 5 Safety Notes Please read the following Safety Notes carefully befor...

Page 6: ...tion Do not operate this product if you see damage to the housing or cables Have the damaged parts replaced by an authorized technician at once Make sure there are no flammable materials close to this product while it is operating Do not cover or plug the output nozzle during operation Do not use the product as a space heater Never carry the product by the power cord or any moving part Always use ...

Page 7: ...ion Advanced No Water protection Anti loose power plug Low fluid consumption 3 5L fluid reservoir 2 hours on full output Built in LCD control 3 pin and 5 pin DMX control Please use DJPOWER professional fluid PRO V PRO A PRO C different fluid will show different stage effect DJPOWER PRO V fog fluid provides an awesome Quick Dissipation effect 2 3 Product Overview Dual Nozzle Bracket Rain proof Shie...

Page 8: ...H SW3000 USER MANUAL V1 4 2 4 Product Dimensions 885 mm 500 mm 455 mm 3 pin DMX Socket 5 pin DMX Socket Power Input for Electronics Power Switch LCD Control Board Breaker ...

Page 9: ...ut Duration full volume 100 0 min Features Physical Thermostat Electronic Thermo Control Adjustable Output Adjustable Fan Speed No Fluid Protection Control On device Manual Control LCD control board Wireless Control Wired Control Control Protocol DMX 512 DMX Channel Range 3 Data Connectors 3 and 5 pin XLR Accessory Diversion Hose 2 pc 3 m 125mm 5 inch Diversion Nozzle Optional 125mm 5 inch Consuma...

Page 10: ...pressing the button with your finger Plug the product s power cord into the power outlet and continue using as recommended 4 4 DMX Linking You can link the H SW3000 to a DMX controller using a 3 or 5 pin DMX connection If using other DMX compatible products with this product you can control each individually with a single DMX controller Instructions for connecting and configuring this product for ...

Page 11: ...E triggers the pump to modify the output volume STOP Enter enables the currently displayed menu or sets the currently selected value into the selected function STOP turns the fog output off 5 3 On device Control Mode Operation 5 3 1 Programming Refer to the Menu Map to understand the menu options The menu map shows the main level and a variable number of programming levels for each option To go to...

Page 12: ...o set fan speed of VOLUME mode 1 100 Humidity 100 Press or to set output humidity of VOLUME mode OFF 25 50 75 100 Timer Interval 600s Press or to set timer interval of TIMER mode 5 600s Timer Duration 300s Press or to set timer duration of TIMER mode 5 300s DMX Address 512 Press or to select DMX starting address 1 512 Fluid Sensor ON Press or to activate deactivate fluid sensor to turn on off no f...

Page 13: ... the starting address in the 001 512 DMX range and uses 3 DMX channels which defines the highest configurable address to 510 to have all channels controllable Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product or press repeatedly MENU button until the LCD shows DMX Address Press or to set desired DMX starting address 5 4 2 DMX Mode Menu Map When co...

Page 14: ...l operable only keep flickering 5 6 2 Clear No Fluid Protection Warning When the machine is under the no fluid protection after refilling the fluid there are three ways to clear the warning Press STOP first then press VOLUME to let the machine run again the warning will disappear until the fluid is pumped and fill the tube Under the DMX control mode bring down channel 1 to OFF value 0 9 then back ...

Page 15: ...ust fluid residue and dirt will degrade performance and cause overheating Remove dust from air vents with air compressor vacuum or soft brush The casing could be cleaned by the damp cloth Test run your DJPOWER H SW3000 on a monthly basis to achieve the best performance 6 2 Storage 6 2 1 Machine Storage Before storing the machine clean it as described in the cleaning procedure above however only fo...

Page 16: ......