H-SW3000 USER MANUAL V1
< 9 >
Display
Description
Parameter Range
Error & Warning Pages
Water Level Low
Refill Water
Fog Fluid Low
Refill
Heating Failure
Contact Service
5.4
DMX Mode & Operation
The Machine H-SW3000 works with a DMX controller.
•
Connect the product to a suitable power outlet.
•
Turn the product on.
•
Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product.
5.4.1
Starting Address
When selecting a starting DMX address, always consider the number of DMX channels. If you choose a starting address that is too high, you
could restrict the access to some of the product
’
s channels.
DJPOWER®
H-SW3000 DMX set the starting address in the 001 - 512 DMX range and uses 3 DMX channels, which defines
the highest configurable address to 510 to have all channels controllable.
Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product, or press
repeatedly
“
MENU
”
button until the LCD shows
“
DMX Address
”
. Press or to set desired DMX starting address.
5.4.2
DMX Mode Menu Map
When connected with DMX controller and receive DMX signal, the display will always show current DMX starting address, that can be
changed anytime by pressing
or .
DMX Address
512
5.4.3
DMX Channel Assignments and Values
Channel
Function
Value
Description
1
Fog Output
000 - 010
No Function
011 - 255
1-100%
2
Fan Speed
000 - 010
No Function
011 - 255
1-100%
3
Humidity
000 - 010
No Function
011 - 062
25% humidity
063 - 122
50% humidity
123
–
183
75% humidity
184 - 255
100% humidity