background image

11 

replaced. 

per instructions on page 11. 

Symptom 

Possible Cause 

Remedy 

e. Compressed air volume
inadequate.

f. Compressed air pressure
inadequate.

g. Compressed air contaminated with
oil or water.

h. Pulse cleaning not working.

i. Pulse cleaning not set up as
required.

j. Reverse jet pulse valves not
operating.

Increase available air volume. Refer to 
page 5. 

Increase air pressure to Maximum of 
100 PSI. 

Eliminate source of contamination and 
purge compressed air line. 

Confirm input power to timer board or 
controller. Refer to pulse control 
manual for further information. 

The “on-time” and “off-time” must be 
set to optimize filter pressure 
differential equilibrium. Refer to pages 
6 and 7 of this manual and to the timer 
board controller manual for additional 
detail. 

Clean, repair or replace valves. 
Refer to page 8. 

Summary of Contents for WB-4000-D

Page 1: ...ion Maintenance Manual WB 4000 D Visit our Website for more information on this product www diversitech ca 1200 55th Avenue Montreal Quebec H8T 3J8 Tel 1 800 361 3733 Fax 1 514 631 9480 info diversite...

Page 2: ...all potential hazards related to dust control equipment or systems Therefore it is imperative that the application and use of this equipment be discussed with an DIVERSITECH distributor and that this...

Page 3: ...NSTALLATION CONSIDERATIONS 4 INSPECTION 4 MECHANICAL INSTALLATION 4 COMPRESSED AIR SUPPLY 5 ELECTRICAL CONTROLS 5 PRE START UP 7 FILTER INSTALLATION 7 START UP 7 SHUT DOWN 8 MAINTENANCE SAFETY 8 MAINT...

Page 4: ...h as Weld fume and grinding dust The cleaned air is then returned to the work space to eliminate the need to exhaust treated air Once the unit is mounted connection of electrical power and compressed...

Page 5: ...ooth Remove and RETAIN the access cover from the desired side of the master booth The slave booth ships with only a cover on the back If the slave is to be positioned back to back with the master remo...

Page 6: ...or from the blower door of the collector The blower motor will need to be energized through a motor starter with over load protection The electrical components must be sized and selected in accordance...

Page 7: ...tart up Be sure the horizontal flange around the venturi is clean With care not to damage filter cartridge place gasket side down on flange Rotate filter slightly to assure no binding and proper locat...

Page 8: ...s to reach an acceptable operating equilibrium point This must be reached gradually in order to not damage the filters by blinding While achieving equilibrium you want to clean the filters more often...

Page 9: ...ntial Pressure during Operation at the beginning of page 7 2 Assure the collected dust is removed from the dust storage container as required 3 Assure the predetermined cleaning schedule is proper to...

Page 10: ...n the system b Unscrew the bonnet bolts and remove the bonnet c Inspect the diaphragm for dust and damage Remove dust with water and replace damaged parts with diaphragm repair kit for 1 or 1 5 valves...

Page 11: ...ion s of motor wiring Rewire motor circuit with proper wire size Dust Discharge from Collector outlet a Filter cartridges not properly installed b Damaged filter cartridge c Damaged filter cap s d Wor...

Page 12: ...ng Increase available air volume Refer to page 5 Increase air pressure to Maximum of 100 PSI Eliminate source of contamination and purge compressed air line Confirm input power to timer board or contr...

Page 13: ...each Plate Filter Cap with gasket 1222 X each T Handle Filter Clamp 1224 X each T Handle Access Door Latch 1023 X each Gasket Door Seal 1214 X feet Valve 1 5 Double Diaphragm 1221 X each Motor XX HP 3...

Page 14: ...n misuse or use above rated capacities FREIGHT CLAIMS Shipments must be inspected upon arrival All Diversitech units are sold ex plant Therefore it is the receiver s responsibility to file any freight...

Reviews: