AIR SUCTION
AIR EXPULSION
CONDENSATE
DRAINAGE
2a. Installation of the unit
IMPORTANT
: Handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will
remain in view.
Hang the air conditioner on the bracket provided on the ceiling by passing the condensate drainage pipe correctly along the air
expulsion pipe and then checking the unit's stability.
Rear grills
electric heating element
Threaded bars
(or chains or other
fastening systems)
Partition wall or
glass (not a bea-
ring wall)
air conditioner
Condensate drainage
Internal conden-
sate drainage
pipe
The pipe protection grills must be applied outside the wall where the unit is installed.
Cut part of the right grill (looking at the unit from the rear) in order to permit the con-
densate drainage pipe to exit correctly (see Figure).
3a. Rear grills
At the end of installation, the grills must be applied to the air circulation pipes.
As above, this particular measure will ensure better unit operation because not only will the air be filtered and therefore the heat
exchange system will remain cleaner (and maintain yield over a longer period of time), but will also prevent the deposit of leaves or
other clogging material in the hosing and infiltration by birds or other small animals.
These grills can be quickly removed and cleaned whenever necessary.
VIEW OF AIR CONDITIONER REAR GRILLS
4a. Position the air conditioner and connect it to the power supply by plugging in the plug. Before starting, make sure that the plug is
adequate to the air conditioner's power absorption and the regulations in force.
37
Air pipe
Insulated air pipe