26
8. Installation of the unit
IMPORTANT
: Handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will
remain in view.
Hang the air conditioner to the bracket provided by passing the condensate drainage pipe correctly along the air expulsion pipe and
then checking the unit's stability.
Rear grills
Electric heating element
Air pipe
Insulated air
pipe
Fastening bracket
Air conditioner
Condensate drain
Internal conden-
sate drainage
pipe
The pipe protection grills must be applied outside the wall where the unit is installed.
Cut part of the right grill (looking at the unit from the rear) in order to permit the con-
densate drainage pipe to exit correctly (see Figure).
9. Rear grills
At the end of installation, the grills must be applied to the air circulation pipes.
As above, this particular measure will ensure better unit operation because not only will the air be filtered and therefore the heat
exchange system will remain cleaner (and maintain yield over a longer period of time), but also will prevent the deposit of leaves or
other clogging material in the pipes and infiltration by birds or other small animals.
These grills can be quickly removed and cleaned whenever necessary.
AIR SUCTION
VIEW OF AIR CONDITIONER REAR GRILLS
AIR EXPULSION
LEFT
RIGHT
CONDENSATE
DRAINAGE
10. Connect the air conditioner to the power supply by plugging in the plug. Before starting, make sure that the plug is adequate to
the air conditioner's power absorption and the regulations in force.